• Keep boiler area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
• This boiler requires regular maintenance and service to operate safely. Follow the instructions contained in this
manual.
• Installation, maintenance, and service must be performed only by an experienced, skilled and knowledgeable
installer or service agency.
• All heating systems should be designed by competent contractors and only persons knowledgeable in the layout
and installation of heating systems should attempt installation of any boiler.
• It is the responsibility of the installing contractor to see that all controls are correctly installed and are operating
properly when the installation is completed.
• Installation is not complete unless a pressure relief valve is installed.
• This boiler is NOT suitable for installation on combustible flooring.
• Do not tamper with or alter the boiler or controls. Retain your contractor or a competent serviceman to assure that
the unit is properly adjusted and maintained.
• Service boiler at least once a year - preferably at the start of the heating season. The inside of the combustion
chamber should also be inspected at the same time. Clean if necessary.
• Have Burner and Controls checked at least once a year or as may be necessitated. Do not operate unit with
jumpered or absent controls or safety devices. Do not operate unit if any control, switch, component, or device
has been subject to water.
• This boiler is designed to burn natural gas only. Do not use gasoline, crankcase drainings, or any oil containing gasoline.
Never burn garbage or paper in this boiler. Do not convert to any solid fuel (i.e. wood, coal). All flammable debris, rags,
paper, wood scraps, etc., should be kept clear of the boiler at all times. Keep the boiler area clean and free of fire hazards.
NOTICE:
1. This boiler has a limited warranty, a copy of which is printed on the back of this manual. It is the responsibility
of the installing contractor to see that all controls are correctly installed and are operating properly when
the installation is complete. The warranty for this boiler is valid only if the boiler has been installed, maintained and
operated in accordance with these instructions.
2. Boilers built for installation at altitudes 2,000-5,000 ft. above sea level have been specially orificed to reduce
gas input rate 4 percent per 1,000 feet above sea level per the National Fuel Gas Code, NFPA 54/ANSI Z223.1.
3. All Series 8HE cast iron boilers are designed, built, marked and tested in accordance with the ASME Boiler and
Pressure Vessel Code, Section IV, Heating Boilers. An ASME Data Label is factory applied to each 8HE jacket,
which indicates the boiler Maximum Allowable working Pressure (MAWP). Each cast iron section is permanently
marked with the MAWP listed on the boiler's ASME Data Label. The MAWP for all Series 8HE Boiler is 50 psi (Water
Only).
It is common and acceptable practice to install these boilers in lower pressure systems, below the boiler MAWP.
Therefore, in addition to Safety Relief Valves set for 50 psi, Burnham Commercial also offers Safety Relief Valves set
for 30 psi (By Special Order Only).