Troubleshooting; Connection Problems - Bosch PXI-CORE Edge controller User Manual

Table of Contents

Advertisement

PXI-CORE Edge controller
6

Troubleshooting

This chapter presents the possible issues with maintenance actions focused on finding and
solving the cause in a structured way. In large systems it can be difficult to find the root cause
of a problem. In that case it is often helpful to create a minimum size system with only the
troubled device and the necessary devices to make it work, using short and proven cables. If
the problem is absent, extend the system in steps until the problem shows up again.
Notice!
Experience and analysis of repair shop data has revealed that in most cases system
i
malfunction is not caused by defective devices, but by wiring errors, configuration errors and
application errors. Read the product documentation carefully, especially the installation
manual, the configuration manual and the release notes. If possible, use the latest software
version (available as free download).
6.1

Connection problems

If you are not successful in connecting to the PXI-CORE graphical user interface via the IPv6
address, fall back to the static IPv4 address of the PXI-CORE edge controller.
To connect the PXI-CORE graphical user interface via the static IPv4 address:
1.
2.
3.
4.
5.
6.
If the assigned IPv4 address of XF51 is unknown:
Notice!
i
Please do not use any address from the 192.168.1.0/24 range on port eth1 (XF51).
If this is necessary, remove the static IP 192.168.1.1 for port eth0 (XF10) to avoid conflicts.
Bosch Security Systems B.V.
Connect the PXI‑CORE port XF51 to your main network.
Connect your preferred device (e.g. PC), via a wired connection, to port XF10.
Assign the static IP‑address 192.168.1.10 to your preferred device.
Open your web browser and enter the address 192.168.1.1.
Accept the risks for the self-signed certificate.
Login with the factory default credentials: Refer to Quick start, page 8 and follow steps 5
through 7.
Check the assigned IPv4 for the Ethernet port XF51 (eth1) in the Connectivity menu.
Make sure you are connected to the web-GUI via the port XF10 [eth0].
If eth1 (XF51) does not have an IPv4 address assigned, you probably do not have a DHCP
server on your main network. You can assign a static IP to eth1 (XF51) via the IPv4 tab,
e.g. 192.168.2.100/24.
Alternatively, depending on your Windows PC settings, the PXI-CORE will also show up in
your Windows Explorer network sessions. Double clicking the icon PXI-CORE opens the
GUI.
User manual
Troubleshooting | en
21
2023-03 | V01 | F01U395004

Advertisement

Table of Contents
loading

This manual is also suitable for:

F.01u.395.004

Table of Contents