Switch/ Sensor, Terminal Section/ Board; Disassembling - Makita DMP180 Repair Manual

Cordless inflator
Hide thumbs Also See for DMP180:
Table of Contents

Advertisement

4-3

Switch/ Sensor, Terminal section/ Board

4-3-1

Disassembling

[2]
[2]
[3]
[2]
[1]
[4]
Fig.8
[1]
Fig.9
[1]
[4]
[5]
Fig.10
[1]
Fig.11
[3]
[2]
1
Remove Switch trigger [1] carefully so that Spring
[2] does not pop out.
2
Remove Screw 3 *10 [1], then remove the
following parts:
 Switch [2]
 Trigger spring-fixed block [3]
 Digital display [4]
 Clamp [5]
3
Loosen Screws 3 *10 [1] (2 pcs), then remove
Power on/off [2].
4
Disconnect Connector [2] from PCB board [1], then
remove Terminal protector [3].
5
Remove PCB board [1] and Battery terminal [4]
from Housing.
6 / 9