1
How to Check Idling Current
a. Aging
The AVR is turned on about 6 minutes for aging.
D
b. Idling After-check
Channel
FL,FR,C,SL,SR,SBL,SBR
Terminals
P6021,P6022,P6023,P6025,P6026,P6027,P6028
*Connect 1/4W 100 ohms resisters in each probe of multi mater .
C
*If the measured value are under 1 mV or over 10 mV, you have to make sure repair.
B
A
1
2
When there is no measured connector on the board:
1. Measure by inserting a like thin pin into the hole of the connector for measurement.
2. Measure via connector as shown.