Cooling Capacity - With High Efficiency Motor Furnaces - York LX Series Technical Manual

Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

5753883-BTG-C-0221
COOLING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings) (Continued)
UNIT MODEL
TW4B3022S
CF/CM/CU36C
TW4B3022S
CF/CM/CU42C
TW4B3022S
CF/CM30C
TW4B3022S
CF/CM36A
TW4B3022S
CF/CM36D
TW4B3022S
CF/CM42D
TW4B3622S
CF/CM/CU36B
TW4B3622S
CF/CM/CU36C
TW4B3622S
CF/CM/CU42C
TW4B3622S
CF/CM/CU48C
TW4B3622S
CF/CM/CU48D
TW4B3622S
CF/CM36D
TW4B3622S
CF/CM42D
TW4B3622S
TW4B4221S
CF/CM/CU42C
TW4B4221S
CF/CM/CU42D
TW4B4221S
CF/CM/CU48C
TW4B4221S
CF/CM/CU48D
TW4B4221S
CF/CM/CU60C
TW4B4221S
CF/CM/CU60D
TW4B4221S
CF/CM64D
TW4B4221S
TW4B4821S
CF/CM/CU48C
TW4B4821S
CF/CM/CU48D
TW4B4821S
CF/CM/CU60C
TW4B4821S
CF/CM/CU60D
TW4B4821S
CF/CM64D
TW4B6021S
CF/CM/CU60C
TW4B6021S
CF/CM/CU60D
TW4B6021S
CF/CM64D
For rated condition information, see the COOLING CAPACITY - With Air Handler Coils table footnotes.
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
— = Not Applicable.
MP Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.

COOLING CAPACITY - With High Efficiency Motor Furnaces

UNIT
MODEL
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL8E060A12UH11
TW4B1821S
TL9E060B12UH11
TW4B1821S
TL9E060B12UH11
TW4B1821S
TL9E060B12UH11
TW4B1821S
TL9E060B12UH11
TW4B1821S
TL9E060B12UH11
10
COIL
MODEL
WIDTH
21
21
21
14.5
24.5
24.5
17.5
21
21
21
24.5
24.5
24.5
CF42B
17.5
21
24.5
21
24.5
21
24.5
24.5
CF42B
17.5
21
24.5
21
24.5
24.5
21
24.5
24.5
FURNACE
MODEL
WIDTH
14.5
14.5
14.5
14.5
14.5
14.5
14.5
14.5
17.5
17.5
17.5
17.5
17.5
CFM RANGE
(MINIMUM–
RATED
MAXIMUM)
CFM
800–1200
1000
800–1200
1000
800–1200
1000
800–1200
900
800–1200
1000
800–1200
1000
1000–1400
1200
1000–1400
1200
1000–1400
1200
1000–1400
1200
1000–1400
1200
1000–1400
1200
1000–1400
1200
1000–1400
1200
1200–1600
1400
1200–1600
1400
1200–1600
1400
1200–1600
1400
1200–1600
1400
1200–1600
1400
1200–1600
1400
1200–1600
1225
1400–1800
1600
1400–1800
1600
1400–1800
1600
1400–1800
1600
1400–1800
1600
1535–1935
1735
1535–1935
1725
1535–1935
1775
1
COIL
RATED
2
MODEL
CFM
CF/CM/CU18A
600
CF/CM/CU18B
700
CF/CM/CU24A
600
CF/CM/CU24B
650
CF/CM/CU30A
600
CF/CM/CU30B
700
CF/CM/CU36B
700
CF/CM36A
625
CF/CM/CU18B
650
CF/CM/CU24B
650
CF/CM/CU30B
625
CF/CM/CU36B
650
CF/CM/CU36C
700
COOLING
NET MBH
SEER
TOTAL
SENS.
29.8
23.2
14.00
30.0
23.4
14.00
29.8
23.4
14.00
29.8
22.2
14.00
29.8
23.2
14.00
30.0
23.4
14.00
36.0
27.6
14.00
36.0
25.0
14.00
36.0
27.6
14.00
36.0
27.8
14.00
36.0
27.8
14.00
36.0
27.6
14.00
36.0
27.6
14.00
36.0
27.6
14.00
40.0
30.0
14.00
40.0
30.0
14.00
40.5
32.0
14.00
40.5
32.0
14.00
41.0
32.5
14.00
41.0
32.5
14.00
41.5
32.5
14.00
38.5
29.0
14.00
47.5
34.2
14.00
47.5
34.2
14.00
48.0
36.0
14.50
48.0
36.0
14.50
48.0
36.0
14.75
56.0
41.0
14.00
56.0
41.0
14.00
57.0
42.0
14.00
COOLING
NET MBH
SEER
TOTAL
SENS.
18.0
14.0
16.00
18.0
14.9
16.25
18.0
14.0
16.25
18.0
14.6
16.25
18.0
13.9
16.25
18.0
14.9
16.25
18.0
14.8
16.25
18.0
14.3
16.25
18.0
14.5
16.00
18.0
14.6
16.25
18.0
14.0
16.25
18.0
14.5
16.25
18.0
14.8
16.25
Johnson Controls Ducted Systems
1
EER
12.20
12.20
12.20
12.20
12.20
12.20
12.20
12.20
12.25
12.25
12.25
12.20
12.25
12.25
12.20
12.20
12.25
12.25
12.25
12.25
12.25
12.20
11.75
11.75
12.25
12.25
12.25
11.75
11.75
11.75
EER
13.25
13.25
13.25
13.25
13.25
13.25
13.25
13.25
13.25
13.25
13.25
13.25
13.25