Download Print this page

Alpine IVA-D900R Service Manual page 12

Mobile multimedia station
Hide thumbs Also See for IVA-D900R:

Advertisement

Step
Description
Connection
MW S-METER
2
Figure 6
Adjustment
LW S-METER
3
Figure 6
Adjustment
NOTE : For the Test Points and Ajustment parts, refer to the Parts Layout on P.W.Boards and Wiring Diagram.
Signal Generator
Dial Control
999kHz
(Input 34dBu,
999kHz
Mod. OFF)
216kHz
(Input 34dBu,
216kHz
Mod. OFF)
Test Point /
P .W.Board
Adjustment
Coordinates
<Auto adjustment>
1. Select MW Mode.
2. Connect to TP1102 and GND for
2 to 3 sec.
TP1102
(NOTE : Perform the auto adjustment
(1-E)
by decreasing input level between 3
TP1121
and 5dBu, and then perform the auto
(1-F)
adjustment again with input level
28dBu.
In this as make sure output at TP1121
shows 1.0±0.1V.)
<Auto adjustment>
1. Select LW Mode.
2. Connect to TP1102 and GND for
2 to 3 sec.
TP1102
(NOTE : Perform the auto adjustment
(1-E)
by decreasing input level between 3
TP1121
and 5dBu, and then perform the auto
(1-F)
adjustment again with input level
28dBu.
In this as make sure output at TP1121
shows 1.0±0.1V.)
TO CONTENTS

Advertisement

loading