Check the positioning of tank components
• Make sure that, the overflow "A", the tank filter "B", and the
flat filters "C" are correctly fitted.
A
C
I
BASIC MACHINE SETUP
I.1
Manual activation
Whenever the detergent containers are replaced, it may be
necessary to activate the dispensers manually in order to fill
the hoses and eliminate any air. Simultaneously press the
buttons, as shown in the figures below. If necessary, repeat
this operation several times.
Detergent dispenser
Rinse-aid dispenser
24
B
C
• Make sure the upper and lower wash and rinse arms are
correctly fitted.
In the appliances with pressure boiler, the diaphragm dis-
penser pump may be manually activated by pressing screw
"D".
I.2
Setting the dispensers
All the operations must be carried out with the machine
switched on, the door open and no cycle selected.
Legend
Increase
Decrease
Confirm or select next parameter
I.2.1
Peristaltic dispenser
Sequential start
1. Press the indicated buttons simultaneously for 5 seconds:
D