F.6

Plumbing connections

• Connect the appliance water supply pipe "WI" (see the
Installation diagram) to the mains, fitting a cut-off tap, the
filter provided and a pressure gauge between the appliance
and the mains (see figure below).
• In models with incorporated water softener and in some
specific models, connect the double non-return valve "B"
supplied and the machine supply pipe (see figure below).
B
• Check that the dynamic water supply pressure, measured
between the appliance and the main, is between 2 bar [200
kPa] and 3 bar [300 kPa] for machines with pressure boiler
and between 0.5 bar [50 kPa] and 7 bar [700 kPa] for
machines with atmospheric boiler (test while dishwasher
tank or boiler is filling with water).
NOTE!
If the pressure is too high, fit a suitable pressure
reducer on the inlet pipe.
– On the model with free-fall drainage:
connect the waste outlet pipe (detail "D" in the Installation
diagram) to the main drain pipe, fitting a trap, or place the
outlet pipe over an "S" trap set into the floor.
– On the model with drain pump:
position the outlet pipe at a height anywhere between 750
mm and 1000 mm from the floor. Depending on the model,
check that from 2 L to 3 L of water flow out of the outlet pipe
during the rinse cycle.
IMPORTANT
Make sure drain pipe does not kink, pinch or
twist, resulting in a water flow restriction.
CAUTION
Always use a new set of joints if you
remove and reinstall the water inlet pipe to
the appliance.
IMPORTANT
Watermark labelled appliances must be installed in
accordance with Plumbing Code of Australia (PCA).
F.7

Plumbing circuits

Appliance with atmospheric water supply - with drain pump
Appliance with pressure water supply - with cold rinse cycle
and with drain pump and
19