Greenheck 473642 Installation, Operation And Maintenance Manual

Greenheck 473642 Installation, Operation And Maintenance Manual

Industrial air circulators

Advertisement

Quick Links

®
Installation, Operation and Maintenance Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the
product described. Protect yourself and others by observing all safety information. Failure to comply with instructions
could result in personal injury and/or property damage! Retain instructions for future reference.
Models IC & ICO
Designed for cooling workers in
factories, warehouses, manufacturing
facilities and garages where humid
and demanding conditions exist. All
circulator heads have high efficiency
corrosion resistant propellers with
aluminum blades. Circulator heads
utilize a vertical tilt/locking adjustment
for directional flow. Wire guards are
gray polyester powder-coated and
comply with OSHA Standard 1910.212
General Safety Information
WARNING
To reduce the risk of fire, electrical shock, or injury
to persons, observe the following:
a. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
b. Before servicing or cleaning unit, switch
power off at service panel and lock the service
disconnecting the means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a
tag, to the service panel.
WARNING
Do not depend on any switch to disconnect power
supply. Always unplug the power cord or turn off
and lock disconnecting means as described.
WARNING
To reduce the risk of fire, electrical shock, or injury
to persons, observe the following:
a. Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including
fire-rated construction.
b. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
Industrial Air Circulators
(1/2" max opening). Fans are UL/cUL Listed
Standard 507. Oscillating units sweep
through 45º or 90º arc.
Permanent split capacitor 2-speed
motors are totally enclosed air over.
Circulators have 115V motors, a pull
chain switch and include a 10 ft. factory
wired, 3-conductor cord with grounded
molded plug. Circulators have a
maximum ambient temperature of 104ºF.
DANGER
Do not place body parts or objects in circulator or
motor openings while motor is connected to the
power source.
WARNING
To reduce the risk of fire or electrical shock, do
not use this fan with any solid-state speed control
device. Do not use a three-prong to two-prong
adapter on the power cord.
WARNING
To reduce the risk of electric shock, do not expose
to water or rain.
WARNING
Do not use general purpose circulators in
flammable, explosive, chemical-laden, or wet or
rainy atmospheres. Use special purpose circulators
designed for particular application. Do not attach
ductwork to a circulator.
1. Read and follow all instructions, cautionary
markings and make sure power source conforms to
the requirement of the equipment.
2. Follow all local electrical and safety codes, as
well as the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA) in the
United States, including fire rated construction.
Ground motor in accordance with NEC Article 250
(grounding).
Models IC/ICO • Industrial Air Circulators
PN 473642
1

Advertisement

loading

Summary of Contents for Greenheck 473642

  • Page 1 PN 473642 ® Industrial Air Circulators Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
  • Page 2 Prior to fully assembling and installing the fan inspect physical damage to the unit after acceptance is not the fan assembly to make sure it is in working order. the responsibility of Greenheck Fan Corporation. 1. Check all fasteners, set screws on the fan, wheel, Unpacking...
  • Page 3 Each fan bears a manufacturer’s nameplate with model number and serial number. This information will assist the local Greenheck representative and the factory in providing service and replacement parts. Before taking any corrective action, make certain unit is not capable of operation during repairs.
  • Page 4 File no. E33599 Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year.