Side discharge variable speed hp
Hide thumbs Also See for 4TWL9048A1000A:

Advertisement

Technician Configuration Menu
S S y y s s t t e e m m p p a a r r a a m m e e t t e e r r s s a a n n d d o o p p t t i i o o n n s s a a r r e e r r e e p p o o r r t t e e d d a a n n d d
s s e e t t f f r r o o m m t t h h e e C C o o n n f f i i g g M M e e n n u u . .
ALERT
CONFIG MENU
MENU
EXT SWITCH
INACTIVE* ACTIVE
MIN AIRFLOW
FACTORY* FACTORY
HTG MAX RPM
HIGH* HIGH
Maximum allowed compressor speed percentage over cooling speed.
LOW - Max Htg Speed equals cooling speed (unit has same max compressor speed as a non-variable speed heat pump)
HIGH - allows compressor to run at the max allowed speed based on ambient conditions (full turbo mode)
MED - caps the max compressor speed half way between the low and high speed options
DEFROST TERM
FACTRY* FACTRY*
CLG BLW OFF
DELAY* DELAY
HTG BLW ON
DELAY* DELAY
HTG BLW OFF
DELAY* DELAY
ID AIR CLG
CMFRT* CMFRT
ID AIR HTG
CMFRT* CMFRT
PFC
AUTO* AUTO
EMI
AUTO* AUTO
RESTORE DFLT?
PRESS ENTER <ENTER>
48
CONTROL
MENU
EXT SWITCH
ACTIVE* INACTIVE
MIN AIRFLOW
MIN AIRFLOW
30% FACTORY
40% FACTORY
HTG MAX RPM
HTG MAX RPM
MED* HIGH
LOW* HIGH
DEFROST TERM
DEFROST TERM
MED FACTRY*
HIGH FACTRY*
Blower Delays Notes
These Blower Delay values are programmed into
the Personaliy Module
Cooling off:
CLG BLW OFF
Heating off:
NONE
DELAY
Heating on:
HTG BLW ON
NONE
DELAY
HTG BLW OFF
NONE
DELAY
ID AIR CLG
EMI Notes
EFF
CMFRT
Introduced with AOC Software Version 2, Fall of 2014.
The drive uses multiple gates (micro relays) to run the
ID AIR HTG
compressor. These gates open and close very quickly. This
EFF
CMFRT
high frequency switching generates low levels of electromag-
netic interference that can interact with other devices in the
home; such as televisions, baby monitors, HAM radios, etc.
PFC
Changing the EMI setting from AUTO to OFF will alter the
ON
AUTO
switching frequency during higher speed compressor
operation which will alter the EMI signal.
EMI
Contact your local FSR if EMI is still impacting devices after
OFF
AUTO
switching EMI to OFF.
ARE YOUR SURE?
PRESS ENTER <ENTER>
VSPD Side Discharge will be
announced as LOAD SHED
See "13.8 External Shutdown"
for more information
MIN AIRFLOW
50% FACTORY
HTG MAX RPM
Introduced with AOC Software
Version 2, Fall of 2014.
90 Seconds
60 Seconds
30 Seconds
4TWL9048A-SF-1C-EN