1-4 NT5K17 Direct Dialing Inward Trunk Card
Technical description
Power requirements
Environmental specifications
PAD switching
553-3001-173 UK Trunk cards description
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
United Kingdom
The technical details of the NT5K17 Direct Dialling Inward trunk card are
outlined below.
Table 1-1 lists the power requirements for the NT5K17 DDI trunk card.
Table 1-1
NT5K17 power requirements
Vo lt age
+ 15. 0 V dc
- 15 V dc
+8. 5 V dc
- 48 V dc
+ 5.0 V dc
Table 1-2 lists the environmental specifications for the NT5K17 DDI card.
Table 1-2
NT5K17 Environmental specifications
Par amet er
Oper at i ng
t emper at ur e
Oper at i ng hum i di ty
St or age t emper at ur e
Loss values for the NT5K17 DDI trunk card are as follows:
Lo ss
PAD out
I dle cu rr ent
195 ma
240 ma
85 ma
50 ma
195 ma
Sp ecif i cat io ns
0 to 50 degr ees C , ambi ent
5 to 95 % RH ( non- c ondensi ng)
- 50 t o + 70 degr ees C
An alo g- t o - Di gi t al
- 4 d B
Ac ti ve cur ren t
195 ma
215 ma
85 ma
500 ma
175 ma
Di gi t al- t o - An alo g
- 3 d B