Alarm And Transfer Wiring (P10) Installation - Northern Telecom Meridian SL-1 Installation Manual

1.5 mb/s remote peripheral equipment cabinet
Hide thumbs Also See for Meridian SL-1:
Table of Contents

Advertisement

2-32
Installation and connections
Chart 2-6

ALARM AND TRANSFER WIRING (P10) INSTALLATION

P10 wiring in cabinets equipped with a built-in cross connect terminal is terminated on the
lower right set of blocks mounted on the rear of the cabinet. This chart describes the method of
extending the P10 wiring to an external cross connect terminal. Connections and designations
for the P10 wiring are the same in both instances.
The P10 wiring is extended from the rear of the QUX19 unit in the cabinet to the cross connect
terminal using a QCAD294-type cable available in the following lengths:
25 ft (7600mm) – QCAD294B1
50 ft (15200 mm) – QCAD294B2
100 ft (30400 mm) – QCAD294B3
One QCAD294 cable is required when the cabinet is served by one or more QUA6 Power Fail
Transfer Units (PFTU). This cable should be designed as cable 1.
A second QCAD294 cable is used to extend the major (MJ) alarm connections to attendant
consoles and to extend remote (REM) alarm connections. This cable should be designated as
cable 2.
STEP PROCEDURE
1
If not previously removed, remove the lower rear cover and EMI shield (if equipped)
from the cabinet.
2
Tag and install one or two (as required) QCAD294 cables through a round access hole
at the rear of the cabinet.
Note: The end of the wires equipped with spade tip connectors will be connected to
TB2 at the rear of the QUX19 power unit. Leave enough wire to reach the connections.
3
Install the cables in to the area reserved for P10 cables at the cross connect terminal.
Note: The cables each contain two black wires, one paired with a white wire and one
with a red wire. Care must be taken not to interchange the black wires
4
Terminate and designate cable 1 (if provided) as follows (Fig. 2-11):
• Terminate the red wire and designate as AUX.
• Terminate the white wire and designate as GRD.
Appendix 1 to 553-2601-200