Page 4 of 24 Base Station installation rules
Don't
553-3601-105 Standard 4.00 September 1996
•
For the PCI protocol, position all the Base Stations at the same cell
center as close together as possible but maintain a minimum center to
center distance of 54 in. (1.35 m). For the CT2Plus protocol, position all
the Base Stations at the same cell center no more than 5 ft (1.5 m) and
no less than 3
1
/
COMPANION
COMPANION
•
Mount the Base Stations as high as possible on walls or ceilings if there
are one or two Base Stations at the cell center.
•
Mount the Base Stations on ceilings if there are three or four Base
Stations at the cell center.
•
Mount Base Stations clear of obstacles such as pipes or ducts.
•
Do not position more than four Base Stations at a cell center.
•
Do not install Base Stations in spaces that transport air (ducts, plenums
or hollow spaces).
•
Do not mount Base Stations in rows.
•
Do not install Base Stations on large concrete or marble columns.
in. (9 cm) from each other.
2
COMPANION
COMPANION