11. PIPING DESIGN
11-3-2. MXZ-SM60NAMHZーU1
Additional refrigerant charge
Refrigerant for the extended piping is not included in the outdoor unit when the unit is shipped from the factory.
Therefore, charge each refrigerant piping system with additional refrigerant at the installation site. In addition, in order to carry out service,
enter the size and length of each liquid pipe and additional refrigerant charge amounts in the spaces provided on the "Refrigerant amount"
plate on the outdoor unit.
Calculation of additional refrigerant charge
• Calculate the additional charge using the liquid pipe size and length of the extended piping.
• Calculate the additional refrigerant charge using the procedure shown to the right, and charge with the additional refrigerant.
• For amounts less than 0.1 kg, round up the calculated additional refrigerant charge.
(For example, if the calculated charge is 32.92 kg, round up the charge to 33.0 kg.)
Additional
refrigerant charge
=
(kg)
[oz]
Example:
MXZ-SM60NAMHZーU1
a ( 15 m [49 ft.] )
P24
Additional
refrigerant charge
=
(kg)
=
=
Additional
refrigerant charge
=
(oz)
=
=
M-P0855
Pipe size
Pipe size
Liquid pipe ø6.35
Liquid pipe ø9.52
+
(m) × 0.027 (kg/m)
(m) × 0.07 (kg/m)
0.29 (oz/ft)
Indoor 1: P24
Indoor 2: P15
Indoor 3: P08
Indoor 4: P08
Total length of each liquid pipe is as follows
ø9.52 [3/8"]
ø6.35 [1/4"]
A ( 30 m [98 ft.] )
b ( 10 m [32 ft.] )
P15
Total length of liquid
Total length of liquid
pipe sized
pipe sized
+
ø9.52 x 0.07 (kg/m)
ø6.35 x 0.027 (kg/m)
45 (m) x 0.07 (kg/m)
40 (m) x 0.027 (kg/m)
3.15
+
7.23
7.3 kg (round-up)
Total length of liquid
Total length of liquid
pipe sized
pipe sized
+
ø
ø
3/8"
0.75 [oz/ft.]
1/4"
x
148 (ft.) x 0.75 [oz/ft.]
131 (ft.) x 0.29 [oz/ft.]
111.00
+
254.99
255 [oz] (round-up)
Total capacity of
connected indoor units
+
– 27 kBtu/h
28 – 54 kBtu/h
0.75 (oz/ft)
55 – kBtu/h
A=ø9.52 [3/8"] 30 m [98 ft.] a=ø9.52 [3/8"] 15 m [49 ft.]
A + a = 30 + 15 = 45 m [148 ft.]
b + c + d = 10 + 10 + 20 = 40 m [131 ft.]
d ( 20 m [65 ft.] )
c ( 10 m [32 ft.] )
P08
Total capacity of
connected indoor units
+
– 27 kBtu/h
28 – 54 kBtu/h
55 – kBtu/h
1.08
3.0
+
Total capacity of
connected indoor units
+
– 27 kBtu/h
0.29 [oz/ft.]
x
28 – 54 kBtu/h
55 – kBtu/h
37.99
+
106
Amount for the
indoor units
1.5 kg (53 oz)
2.5 kg (88 oz)
3.0 kg (106 oz)
b=ø6.35 [1/4"] 10 m [33 ft.]
c=ø6.35 [1/4"] 10 m [33 ft.]
d=ø6.35 [1/4"] 20 m [66 ft.]
P08
Amount for the
indoor units
1.5 kg (53 oz)
2.5 kg (88 oz)
3.0 kg (106 oz)
Amount for the
indoor units
1.5 kg (53 oz)
2.5 kg (88 oz)
3.0 kg (106 oz)