Panasonic CS-S9TKV Service Manual page 67

Hide thumbs Also See for CS-S9TKV:
Table of Contents

Advertisement

4
Connect the power supply cord and connection cable between indoor unit and outdoor unit according to the
diagram below.
5
Secure the power supply cord and connection cable onto the control board with the holder.
6
Attach the control board cover back to the original position with screw.
7
For wire stripping and connection requirement, refer to instruction 11.2.4.1 of indoor unit.
Isolating Devices (Disconnecting means) should have minimum 3.0 mm contact gap.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than the other AC wires for safety reason
11.3.5
Piping Insulation
1
Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation
Diagram. Please wrap the insulated piping end to prevent water from going inside the piping.
2
If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by
using POLY-E FOAM with thickness 6 mm or above.
Terminals on the indoor unit
Colour of wires (connection cable)
Terminals on the outdoor unit
(Power supply cord)
Terminals on the isolating
devices
(Disconnecting means)
L N
1 2
Earth wire
longer than
others
AC wires
for safety
reason
Power
supply
cord
Isolating
Devices
WARNING
This equipment must be properly earthed.
67
1
2
3
L
N
1
2
3
(L) (N)
Terminal
Board
3
Earth wire
longer than
others
AC wires
for safety
reason
Holder
Indoor &
outdoor
connection
cable
Indoor unit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents