Manage Ports & Your Ss15; Port Modes; Switching Port Modes - CAMBRIONIX SS15 User Manual

Hide thumbs Also See for SS15:
Table of Contents

Advertisement

5.4. Manage Ports & Your SS15
Each port on your SS15 can be managed either individually, or all together. You can turn the
ports off and on, change the port mode, or change the charging profiles. This can be done either
through LiveViewer, or by connecting to the hub via the API.

5.4.1 Port Modes

Turn specific ports or the whole hub to charge mode (data lines open but
Charge
hub emulates an OEM  charger for charging)
Sync
Turn specific ports or the whole hub to sync mode
Biased
Detect the presence of a device but it will not sync or charge it
Turn specific ports on or off or switch the whole hub on or off (no power
Off
and no data channels open, mimics unplugging the device)

5.4.2 Switching port modes

You can switch between port modes by using our LiveViewer application or by using the CLI. If
you switch a port off then this will stop any connection taking place to the USB  device and
would mimic unplugging the USB device completely from the host system.
If you are in Sync mode and then switch to Charge mode the USB device will disconnect briefly
whilst the profiling process takes place. Once the profiling has taken place, and a charging
profile is selected, the device will then draw a charge rate, which will be defined by the charging
controller within the USB  device. The charging profile will limit the maximum amount that the
device is able to draw.
If you are in Off or Charge mode and switch to Sync mode the USB device will disconnect briefly
whilst a data connection is opened, the USB  device will then become available to the host as if
the USB device is connected directly to the host, and will be able to sync data at a maximum
rate of 5  Gbps. The SS15 will also charge the device whilst connected. It is impossible to have a
data connection to a USB  device without any power negotiating, you can reduce the charging
rates available by disabling CDP (Charging downstream port).
You can disable CDP  through NVRAM  settings either by going through the hub settings and
turning "Sync charge" off or through the API  and disabling it via code. For example, using the
command line, the instructions would be as below.