FOREWORD
INTENDED USE

VISIBILITY FROM OPERATOR'S SEAT

The visibility standards (ISO 5006) for this machine require a view shown in the diagram below.
VISIBILITY IN IMMEDIATE AREA
The visibility of this machine in the area 1 m (3 ft 3in) from the outside surface of the machine at a height of 1.5 m
(4 ft 11 in) is shown in the diagram below. The hatched area (A) shows the area where the view is blocked by part
of the machine when mirrors or other aids to visibility are installed as standard. Please be fully aware that there are
places that cannot be seen when operating the machine.
12-M RADIUS VISIBILITY
The visibility at a radius of 12 m from the machine is as shown in the diagram below. The hatched areas (B) show
the areas where the view is blocked when mirrors or other aids to visibility are installed as standard. Please be fully
aware that there are places that cannot be seen when operating the machine.
1 - 5