Error Codes And Sensor Malfunctions - EdgeStar Koldfront WAC8002WCO Service Manual

Cool only window air conditioner
Table of Contents

Advertisement

forming on cooling
The directional louvers on the
coil behind front grill.
front are positioned improperly.
Front of unit is blocked by
drapes, blinds, furniture, etc.
and is restricting air distribution.
Doors, windows, registers, etc.
are open and cold air is
escaping.
Unit recently turned on in hot
room.
Dirty air filter- air restricted.
Air conditioner turns
on and off
Outside temperature is
frequently.
extremely hot.
Air movement sound.
Noise when unit is
cooling.
Window vibration - poor
installation.
Water dripping
INSIDE when unit is
Improper installation.
cooling.
Water dripping
Unit removing large quantity of
OUTSIDE when unit
moisture from humid room.
is cooling.
Room too cold
Set temperature is too low.

7.2 Error Codes and Sensor Malfunctions

Display
Error
AS
Room temperature sensor error.*
LO
Room sensor is an open circuit.*
HI
Room sensor is a short circuit.*
Defrost sensor is open or short
ES
circuit.
If display indicates an AS error, use the mode button to select "Fan" and LO or HI will be
displayed to indicate the underlying condition. See section 7.3 for additional information.
All manuals and user guides at all-guides.com
Solution
1) Check sensor connection to main PCB and secure
any detached or loose connections.
2) Check sensor wire for damage and repair if
possible.
3) Test sensor (see table 7.3) Replace sensor if
defective.
Position louvers for better air distribution.
Clear blockage in front of unit.
Close doors, windows, registers.
Allow additional time for unit to remove stored
heat from walls, ceiling, floor and furniture.
Clean air filter.
Set FAN speed to a Higher setting to push
more air through the coils.
This is normal. If too loud, set to a slower FAN
setting.
Refer to installation instructions or check with
installer.
Tilt air conditioner slightly downward toward
the outside to allow water drainage. Refer to
installation instructions - check with installer.
This is normal during very humid days.
Increase the set temperature.
23