The values are specified as follows:
7
6
5
1
2
1 Mark data
+ = 0
– = 1
2 Numerical value data
The values of the CONTROL data which is defined by
this command are applied to the current monitor state.

Display Data (24H)

Defines PITCH, DOT PHASE, SIZE H, SIZE V, SHIFT
H and SHIFT V data in the USER CONFIG menu.
The command has two sections.
1. The element of USER CONFIG data being sent
2. USER CONFIG data value
1. The element of USER CONFIG data being
sent
The element of USER CONFIG data being sent is the
first byte of the command block of the message.
Several items of USER CONFIG data can be specified
in one message stream. If 1 is indicated in the bit
position, the data is changed and 0 is indicated, no data
is changed.
If the byte value is 0, no data are changed and an ACK
is issued. If the RESET value is set to 1, all items are
specified to the default setting.
The values are specified as follows:
7
6
5
1
2
1 RESET
2 PITCH
3 DOT PHASE
4 SIZE H
5 SIZE V
6 SHIFT H
7 SHIFT V
2. USER CONFIG data value
Each adjustment value is one byte of data (8 bit data,
MSB is a mark data. If the value is a negative number, it
is represented as a complement of 2). The data are
defined from the subordinate bit element to the
superordinate bit element in the data bytes. For
8
Command Description
4
3
2
1
0
4
3
2
1
0
3
4
5
6 7
example, if the data to be adjusted are SIZE H and
SHIFT H, then the first byte of data bytes is for SHIFT
H and the next byte is for SIZE H.
Adjustment Item Max.
PITCH
0
DOT PHASE
0
SIZE H
–100
+100
SIZE V
–100
+100
SHIFT H
*
SHIFT V
*
* The maximum and minimum values vary according to the input signal
(resolution). See "Maximum and minimum values of SHIFT H and
SHIFT V" (page 34).
The values are specified as follows:
7
6
5
4
1
2
1 Mark data
+ = 0
= 1
2 Numerical value data
This is not the data to increase or decrease the setting.
Enter the adjustment value.
The standard value (center value) of the PITCH data is
not always 0 (zero). It differs depending on the input
signals. The maximum and minimum values
mentioned above are variable values to each standard
value.

User Memory (25H)

Controls LOAD/SAVE of each data set in the USER
MEMORY menu.
The values are specified as follows:
7
6
5
4
1
2
1 Control data
LOAD = 01
SAVE = 10
2 User memory number
Specifies the number 01 to 20.
If a number other than the above except 00 is
specified, an ACK is issued.
When 00 is specified, the data is applied as follows:
If LOAD (01) is specified in 1, the default setting is
applied.
Min.
32
63
*
*
3
2
1
0
3
2
1
0