Download Print this page

3Com AirProtect Enterprise Engine 6100 Quick Setup Manual

Hide thumbs Also See for AirProtect Enterprise Engine 6100:

Advertisement

Quick Links

®
3Com
AirProtect Enterprise
Engine 6100
Quick Setup Guide
www.3com.com
Part Number: 10015863 Rev. BA
March 2008
Copyright © 2008 3Com Corporation. All rights reserved
 

Advertisement

loading

Summary of Contents for 3Com AirProtect Enterprise Engine 6100

  • Page 1 ® 3Com AirProtect Enterprise Engine 6100 Quick Setup Guide www.3com.com Part Number: 10015863 Rev. BA March 2008 Copyright © 2008 3Com Corporation. All rights reserved  ...
  • Page 2 Copyright © 2003 – 2008 3Com Corporation and its Licensors. All Rights Reserved. 3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
  • Page 3 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide  Step 1: 3Com AirProtect Enterprise Appliance and Sensor Overview  The front panel of the appliance has a power switch and status LEDs as shown in the figure below.    The rear panel of the appliance has power and port connectors as shown in the figure below.    The front panel of the Sensor has status LEDs as shown in the figure below.    The rear panel of the Sensor has power and port connectors as shown in the figure below.     ...
  • Page 4: Step 2: Mount The Appliance

    3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide  Step 2: Mount the Appliance  Place the appliance on the rack and mount the appliance using the rack mounting accessories.    Step 3: Power up the Appliance  Connect the power cable as shown in the figure below and press the power switch on the front panel of the appliance.    Important! On connecting the Power cable, the Power LED should turn solid green. If this does not happen, refer to the 3Com AirProtect  Enterprise Installation Guide.             ...
  • Page 5: Step 4: Connect The Appliance To The Network

    3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide  Step 4: Connect the Appliance to the Network  Connect the appliance to the network using the network interface cable as shown in the figure below.    Warning! The default IP address of the appliance is 192.168.1.246. Please ensure that no other device on your network uses the same IP  address as the appliance. Connect the network interface port on the appliance to the desired subnet using the network interface cable  provided to you. Do not connect the High Availability (HA) Interface port to the subnet.  Step 5: Access the 3Com AirProtect Enterprise Server  A. Connect your computer to the same subnet where the Server is connected.  Change your computer IP address to 192.168.1.XXX. For example, 192.168.1.244.  C. Access the 3Com AirProtect Enterprise Server using SSH as shown in the figure below.    D. Login using the Username: config and Password: password.                       ...
  • Page 6 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide  Step 6: Complete the Server Initialization and Setup Wizard  Follow the steps in the Server Initialization and Setup Wizard to configure the 3Com AirProtect Enterprise Server.  Important! On the Date and Time settings screen‐Step 3, if the day exceeds 31 and the month exceeds 12, 3Com AirProtect Enterprise  automatically sets the day to 31 and month to 12.    Important! You need to reboot the Server on completion of the Initialization and Setup Wizard before you access the Server  Console (GUI). Step 7: Set up the Server DNS Entry  Add a DNS entry ‘wifi‐security‐server’ in your organization’s/enterprise DNS server. This entry should point to the IP  Address of the Server configured in Step 6 (Complete Server Initialization and Setup Wizard)—Sub step 2 (Change the  Network Settings).  Adding this entry serves two purposes:  Sensors can connect to the Server with “zero configuration” if they are connected to a DHCP enabled subnet.  You can access the Server using the address ‘https:// wifi‐security‐server’.    Step 8: Access the 3Com AirProtect Enterprise Console  Important! The minimum system requirements to access the 3Com AirProtect Enterprise Console are a laptop with Intel P4 X86 1.4 GHz  Processor, 512 MB RAM, Windows 2000 or XP Operating System, IE 5.5 or higher, and JRE 1 5 or higher.  Type ‘https:// wifi‐security‐server’ to access the 3Com AirProtect Enterprise Console.      The 3Com AirProtect Enterprise Console can take up to 2 minutes to load.  Important! Pop‐up blockers (if any) must be disabled on the Web browser. The Reuse windows for launching shortcuts option in  Tools Internet Options Advanced should be deselected in the Internet Explorer Web browser.  Click Yes on each of the Security Alert/Warning pop‐up screens.  Activate the license by supplying the license key file shipped with the appliance. Browse to the location of the license  key file and select it. Click <Apply>.     ...
  • Page 7 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide    If the license key is valid, you will see the Login screen. Otherwise, you will see an error message.  Log in using the default username: admin and password: password.      Important! If you see a blank screen instead of the 3Com AirProtect Enterprise Console Login screen in the pop‐up window, despite  having Sun JRE 1.5, then Sun JRE 1.5 may not be the default plug‐in for your Web browser. To ensure that Sun JRE 1.5 is the  default plug‐in for your Web browser, do the following:  1. If you see a “Java Cup” icon in the system tray, right click it and select “Open Control Panel”.  2. If you do not see the icon, click Start  Settings  Control Panel and double‐click the Java Plug‐in icon.  3. Once the Java Control Panel dialog is open, go to the Advanced tab and select the checkbox Internet Explorer.  ...
  • Page 8 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide    On the End User License Agreement (EULA) screen, read the agreement carefully and select I have read and agree to  the Licensing Agreement above. Click <Next>.      If you see the Welcome screen, close the window. You are done with the Server setup. You can revisit the Welcome  screen later.     ...
  • Page 9 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide    Step 9: Power up and Connect Sensors to the Network  Power and Connect the Sensor to the Network  Ensure that the 3Com AirProtect Enterprise Server is already running on your network.  Note: Make sure that a DNS entry ‘wifi‐security‐server’ is set up on all DNS Servers. This entry should point to the IP address of the  Server. Otherwise, configure the Sensor manually. Please refer to the 3Com AirProtect Enterprise Installation Guide for details.  Use network interface cables to connect Sensors to all the network segments (subnets) that need to be protected.  Make sure that the network segment is DHCP enabled. Otherwise, configure the IP address of the Sensor manually.      Note: Log in to the Server using SSH. Run the command ‘get sensor list’ to check if all the Sensors added have been detected by the Server.  If all the Sensors are connected, go to the next step. If some Sensors are not connected, then you may need to configure the Sensors  manually.   ...
  • Page 10 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide  Wait for the status of the LEDs to stabilize. This process may take up to 2 minutes.  If all LEDs glow green, then the Sensor is operational and connected to the 3Com AirProtect Enterprise Server.      If Step D succeeds, the Sensor is now fully operational and is ready to protect your network.  Important! If the LED status at the end of Step 1A or 2D does not match the status shown in this Quick Setup Guide, refer to the 3Com  AirProtect Enterprise Installation Guide for more details.   ...
  • Page 11 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide  Step 10: Begin the 3Com AirProtect Enterprise System Setup Wizard  Log in to the 3Com AirProtect Enterprise Console using the default username: admin and password: password.  The Welcome to 3Com AirProtect Enterprise System Setup Wizard screen appears as shown in the following figure.      This wizard takes you through the steps to help you initialize 3Com AirProtect Enterprise. Click <Next> on each screen to  proceed to the next step. To go back to a previous step, click <Previous>. To exit the setup wizard at any point, click <Exit>.  You can take a tour of this wizard later through the 3Com AirProtect Enterprise Console from  Administration Global Tab System Settings Wizards and configure the appropriate settings. Click <Start>.  Step 11: Complete the 3Com AirProtect Enterprise System Setup Wizard  Follow the steps in the System Setup Wizard to configure settings, classify devices, set up locations and devices, configure  events and reports and so on. Click the   icon to view details. The End of the Setup Wizard screen is the Dashboard screen  and appears as shown in the following figure.   ...
  • Page 12 3Com® AirProtect Enterprise Engine 6100 Quick Setup Guide    The 3Com AirProtect Enterprise Server is installed and configured!   ...