. Â NOTE Information that requires special emphasis . Â TIP Alternate techniques or clarifying information. SHALL: This word is understood to be mandatory . SHOULD: This word is understood to be advisory . Sentry Equipment Corp...
. If the sample container is removed from the sampler, do not insert any body part or other item into the sample discharge port . Crushing will occur . Sentry ISOLOK SAL-DBB Sampler...
. The temperature rating of the ISOLOK SAL-DBB sampler is defined by the plunger seals . The plunger seals are selected based on material compatibility and temperature of the process being sampled .
Screw Mount Containers Standard sampler body is provided with a 1-inch tri-clamp discharge port . Adapters to fit threaded sample collection bottles are available from Sentry Equipment . These adapters have a suitable connection and mount onto the discharge port .
Determine which type of line adapter has been provided: Bolt-on line adapters are designed to bolt onto existing Sentry SAL-B line adapters . Weld-on line adapters are designed for new installations through the wall of larger diameter pipes or sides of tanks .
(RETRACT), and the time to wait between samples in the PARK position . When used with a Sentry SAL-DBB controller, go to the SETPOINT menu and set the EXTEND, RETRACT, and PARK setpoints .
3. Use an extended reach 3/8˝ tee handle hex wrench to engage the hex socket in the rear of the piston rod . 4. Use a 3/8˝ hex wrench to loosen the plunger spindle at the front of the sampler . Sentry Equipment Corp...
. To adjust the stem packing nut, remove the block valve handle and loosen or tighten the packing nut using the optional valve packing nut wrench (see DBB Tools list) . Sentry ISOLOK SAL-DBB Sampler...
. Failure to keep screws or connectors properly secured could result in leakage or damage . 3. Do not weld, machine, or otherwise modify sampler or control in any manner . Consult Sentry Equipment before undertaking any changes . Follow your plant safety procedures whenever maintenance or inspection is required on this equipment .
Replacements Parts & Consumables—Order your replacement parts and consumables . Sentry ProShield Services – select from four ProShield Guardian service plans providing diff erent levels of support to protect your large system investments with regularly scheduled maintenance .
Page 16