Peripheral Devices - Mitsubishi Electric FR-E540 K-EC Series Instruction Manual

Large capacity inverter
Hide thumbs Also See for FR-E540 K-EC Series:
Table of Contents

Advertisement

2.3.6 Peripheral devices

(1) Selection of peripheral devices
Check the capacity of the motor to be used with the inverter you purchased.
Appropriate peripheral devices must be selected according to the capacity.
Refer to the following list and prepare appropriate peripheral devices:
Motor
Inverter Type
Output
(kW)
FR-E540-0.4K-EC
0.4
FR-E540-0.75K-EC
0.75
FR-E540-1.5K-EC
1.5
FR-E540-2.2K-EC
2.2
FR-E540-3.7K-EC
3.7
FR-E540-5.5K-EC
5.5
FR-E540-7.5K-EC
7.5
FR-E520S-0.4K-EC
0.4
FR-E520S-0.75K-EC 0.75
FR-E520S-1.5K-EC
1.5
FR-E520S-2.2K-EC
2.2
Note: 1. Select the type of the no-fuse breaker
(NFB) in response to the power
supply capacity.
2. The power supply cable size of the
motor indicated assumes that its
length is 20m.
3. The inverter input side magnetic
contactor
to
between the applicable ranges A, B
and C shown on the right, depending
on the power supply capacity and
wiring length. For the FR-E520S-0.4K to 0.75K-EC choose the S-N10 when
the power factor improving reactor (FR-BEL or FR-BAL) is used.
4. When the inverter capacity is greater than the motor capacity, choose the
breaker and magnetic contactor in accordance with the inverter type and
choose the cables and power factor improving reactor in accordance with
the motor output.
Power
No-Fuse Breaker (NFB) or Earth Leakage
Supply
Circuit Breaker (NV)
Capacity
Standard
(kVA)
1.5
Type NF30, NV30 5A
2.5
Type NF30, NV30 5A
4.5
Type NF30, NV30 10A
5.5
Type NF30, NV30 15A
9
Type NF30, NV30 20A
12
Type NF30, NV30 30A
17
Type NF30, NV30 30A
1.5
Type NF30, NV30 10A
2.5
Type NF30, NV30 15A
4.5
Type NF30, NV30 20A
5.5
Type NF30, NV30 30A
be
chosen
differs
39
INSTALLATION AND WIRING
Magnetic Contactor
With power factor
A
improving reactor
Type NF30, NV30 5A
Type NF30, NV30 5A
Type NF30, NV30 10A
Type NF30, NV30 10A
Type NF30, NV30 15A
Type NF30, NV30 20A
Type NF30, NV30 30A
Type NF30, NV30 10A S-N21 S-N25 S-K50
Type NF30, NV30 15A S-N21 S-N25 S-K50
Type NF30, NV30 20A
Type NF30, NV30 30A
Power factor
improving
AC reactor
range
500
B
C
50
0
10
20 Wiring length(m)
Note: Power supply used has the above
recommended size.
(MC)
B
C
S-N10
S-N10
S-N10
S-N20
S-N20
S-N20
S-N20
S-N21
S-N25
A

Hide quick links: