Download Print this page

Daikin RKS50FVMV Removal Procedure page 7

Advertisement

Si001269EA
Step
3
Remove the nut of the
outdoor fan.
Remove the outdoor
4
fan.
Remove the 2 lower
5
screws from the fan
motor first.
6
Then, remove the 2
upper screws.
Release the fan motor
7
lead wire from the 2
hooks and pull out the
fan motor.
Removal Procedure
Procedure
Fan motor lead wire
Outdoor fan
(R17560)
Fan motor
(R5264)
Outdoor Fan / Fan Motor
Points
Nut size: M6
10 mm
(0.39 inch)
(R18954)
When reassembling, align
the
mark of the outdoor
fan with the D-cut section of
the motor shaft.
Be sure to remove the lower
screws first. If the top screws
are removed first, the fan
motor may tilt down or fall
and cause injury because its
center of gravity is shifted to
the front.
When reassembling, put the
fan motor lead wire through
the back of the fan motor so
as not to be entangled with
the outdoor fan.
(R17733)
5

Advertisement

loading

This manual is also suitable for:

Rxs50fvmvRks60fvmvRxs60fvmvRxs50gvmvRxs60gvmv