Si001269EA
Step
4
Remove the sound
blanket (outer).
Remove the sound
5
blanket (inner).
6
Release the discharge
pipe thermistor.
Cut the clamp and pull
7
out the outdoor heat
exchanger thermistor.
Removal Procedure
Procedure
Sound blanket
(inner)
Discharge pipe thermistor
Clamp
Sound Blankets / Thermistors
Since the piping ports are
Sound blanket
torn easily, remove the
(outer)
sound blankets carefully.
(R17062)
(R20212)
Be careful not to lose the
clip for the thermistor.
(R17061)
Outdoor heat
exchanger
thermistor
(R5292)
Points
Clip
(R12287)