Rack-mounting procedure at a glance

Figure2-5 Rack-mounting procedure
Select an installation
position for the mounting
brackets (near the power
supply side or port side)
NOTE:
If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate
location, and attach the switch to the rack with the mounting brackets.

Chassis dimensions and rack requirements

Figure2-6 Chassis dimensions with the mounting brackets installed at the port side
(1) Power supply handle
Figure2-7 Chassis dimensions with the mounting brackets installed at the power supply side
(1) Power supply handle
Follow these guidelines when you install the switch in a 19-inch rack:
The distance between the front and rear posts of the rack must meet the requirements
described in Table2-3.
To secure the switch to the rack, you must install not only mounting brackets, but also chassis
rails and slide rails.
Attach the
Attach the
mounting
chassis rails to
brackets to the
the switch
switch
2-8
Connect the
Attach the slide
grounding cable to a
rails to the rack
grounding point
(2) Mounting bracket
(2) Mounting bracket
Mount the switch
in the rack