Temperature Recorder (Optional); Rs485 Interface; Cleaning; Fan - Dometic ML360 CS Operating Instructions Manual

Table of Contents

Advertisement

Temperature recorder (optional)

• The recorder is used to record the temperature
response over a certain period. This period can
either be set to 7 days (preset) or 24 hours, as
required. To change the setting, proceed as
follows: raise the lever with the recording stylus
and take the lock nut off the recorder axis. You
can now remove the recorder disk. Now pull the
recorder axis to remove the assembly from the
housing. The switch with which to set the
required time period is located on the side of the
assembly.
• The disks for the two time periods are different.
Make sure that you insert the correct disk.
• The clockwork for the recorder is powered by a
1.5V AA battery. This is located on the underside
of the recorder assembly.

RS485 Interface

• The unit is equiped with an RS485 interface. You
can use this interface to connect the unit to a PC
or to network it to other refrigerating equipment.
• For information about connection options and
software, contact your local service centre.

Cleaning

• The refrigerator should be cleaned and if
necessary disinfected before you use it for the
first time and then at regular intervals thereafter.

Fan

• When units are fitted with internal ventilation, it
is vital that the interior fan is always in working
order.
!
• To replace the stylus, take the old stylus out of
the stylus retainer and push the new one into the
guides until it stops. Be careful not to touch the
stylus with your fingers.
• When re-assembling, make sure that the lock nut
is sited correctly.
• Only use gentle cleaning agents. Never use
aggressive or caustic cleaning agents, scouring
powder, steel wool, abrasive sponges or chemical
solvents. When cleaning, make sure that no fluids
of any kind run into the ventilation housing.
• Before restarting the unit after cleaning, the
interior must be thoroughly dried.
• To prevent warm outside air being sucked in
unnecessarily when the door is open, the fan
switches off when the door is opened.
• The airflow to the fan must never be impeded.
The ventilation slots must therefore never be
blocked or covered.