Air temperature at Air temperature at indoor outdoor coil °F coil °F Minimum Maximum Minimum Maximum cool heat cool heat cool heat cool heat R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Never leave a suction-line drier in the system kit to prevent the outdoor unit from taking in cold air longer than 50 h of run time. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
32°F. Elevate the unit sufficiently to prevent any blockage of the air entrances by snow in areas where there will be snow R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
NOTICE Replacements for the liquid line drier must be bi-flow and an approved replacement from Source 1. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
500 microns or less. See SECTION V: Evacuation. Do not use the system refrigerant in the outdoor unit to purge or leak test. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Do not over-torque. Do not use slip joint pliers. This will distort the aluminum distributor and the brass fitting (potentially causing leaks). R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
15 ft (4.6 m) of refrigerant piping, and the smallest indoor coil or air handler match-up. Some indoor coil or air handler matches may require additional charge. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Local, National, Fire, Safety and Electrical Codes. This unit must be grounded with a separate ground wire in accordance with the above codes. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Page 29
30, 36, 42, 48, and 60 models only) Figure 12: Outdoor unit control box (208/230 V single- phase 18 and 24 models only) R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Figure 13: Standard MS HP - Premium ECM AHU Figure 14: Standard MS HP - Premium ECM Gas Furnace Figure 15: Standard MS HP - Standard ECM AHU R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Page 31
Figure 16: Standard MS HP - Standard ECM Gas Furnace Figure 17: Standard SS HP - Premium ECM AHU Figure 18: Standard SS HP - Premium ECM Gas Furnace R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
If a dehumidification control is installed, it is recommended that a minimum air flow of 325 CFM/ton be supplied at all times. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Test pin short removed Terminate defrost as normal. Test pin short not removed Continue defrost cycle until TEST connection removed. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
Page 34
(0.1 s ON / 0.1 s OFF) to indicate that the error memory is clear. Figure 21: Heat pump flow diagram R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
For instance, a flash code entry of 3 indicates that Control failure 10 Flashes the control energizes the output for three 1/3 s on, 1/3 s R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
40 min timer. When this timer expires, control does not act upon the jumper changes until the R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
When applicable, instruct the owner that the compressor remainder of the call. is equipped with a crankcase heater to prevent the migration of refrigerant to the compressor during the R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...
It is unlawful to knowingly vent, release or discharge refrigerant into the open air during repair, service, maintenance, or the final disposal of this unit. R-410A Outdoor Split-System Heat Pump Installation Manual - YH2E / THE2 / RHP143 Series Johnson Controls Ducted Systems...