Installer Programming Block Diagram - Interlogix ACL875SU-BS Installation Manual

Standalone keypad and biometric swipe reader

Advertisement

Wait 5 seconds (until fast blinking)
Swipe the INSTALLER Finger
and start counting seconds
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
Relay 2 is available if the reader is used with remote relay unit with 2 relays (ACL870FL-PB and ACL800FL-RU2). Consult the installer if Relay 2 is
available in your system.
BUZZER ON/OFF
Action
Swipe Installer Finger 3 times
Wait 5 seconds (until fast blinking)
Swipe Installer Finger
BACKLIGHT ON/OFF
Action
Swipe Installer Finger 4 times
Wait 5 seconds (until fast blinking)
Swipe Installer Finger

Installer Programming block diagram

Swipe the Installer Finger 1 to 4 times depending of the desired menu
6 / 7
X 1
X 1
Finger
X 3
X 1
Finger
X 4
X 1
Only in combination with
ACL870FL-PB andACL800FL-RU2
fast
beeps on 1 second
blinking
fast
short + long beep
blinking
Backlight
slow
blinking
fast
short + long beep
blinking
Backlight
slow
blinking
fast
short + long beep
blinking
short beep
Buzzer Sound
short beep
short beep
Buzzer Sound
short beep
short beep
P/N 1073523A• REV 00.00 • ISS 4JUL18