Trane 4YCZ6024A1060A Installation And Operation Manual page 6

Single packaged gas/electric 16 seer convertible, 2 - 5 ton, 60 - 115 kbtu, r-410a
Table of Contents

Advertisement

I I n n t t r r o o d d u u c c t t i i o o n n , , U U n n i i t t I I n n s s p p e e c c t t i i o o n n a a n n d d S S p p e e c c i i f f i i c c a a t t i i o o n n
UNITS
F.L. Amps
FILTER / FURNISHED
Type Recommended
Recmd. Face Area (sq. ft) (g)
REFRIGERANT
Charge (lbs.)
Subcooling
(a)
Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on AHRI Standard 210/240. Noise calculated in
accordance with AHRI Standard 270.
(b)
Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per
manufacturer's recommendation with a clean resistance of 0.05" W.C.
(c)
Sound Power values are not adjusted for AHRI 270-95 tonal corrections
(d)
All models are certified to UL 1995. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft.
elevation.
(e)
Convertible to LPG.
(f)
This value is approximate. For more precise value, see Unit Nameplate.
(g)
Standard Air - Dry Coil - Outdoor.
(h)
Based on U.S. Government Standard Tests.
UNITS
RATED Volts/PH/Hz
Performance Cooling BTUH
(a)
Indoor Airflow (CFM)
Power Input (KW)
EER H/L/SEER BTU/Watt-Hr
(b)
Sound Power Rating [dB(A)]
(c)
PERFORMANCE HEATING
(d)
Input BTUH-1st Stage
Input BTUH-2nd Stage
AFUE
Temp rise-Min/Max (F°)
Orifice Qty/Drill Size (Nat Gas)
POWER CONN. — V/Ph/Hz
Min. Brch. Cir. Ampacity
(f)
Fuse Size — Max/Rec (A)
COMPRESSOR
VOLTS/PH/HZ
R.L. Amps — L.R. Amps
OUTDOOR COIL — TYPE
Rows/F.P.I
Face Area (sq. ft.)
Tube Size (in.)
Refrigerant Control
INDOOR COIL — TYPE
Rows/F.P.I
Face Area (sq. ft.)
Tube Size (in.)
Refrigeration Control
6
4YCZ6024
*060
56250 [72000]
(e)
4YCZ6036
*070[*090]
LOCATED ON UNIT NAMEPLATE
THROWAWAY
4.0
LOCATED ON UNIT NAMEPLATE
LOCATED ON UNIT NAMEPLATE
4YCZ6036
*075[*096]
208-230/3/60 - 3 PHASE
35600
1175
LOCATED ON UNIT NAMEPLATE
12 / 13.6 / 16.6
70.0
75000 [96000]
96000 [120000]
79.5 [80]
30 / 60
[40 / 70]
2 / #33
[3 / #37]
208-230/3/60 - 3 PHASE
LOCATED ON UNIT NAMEPLATE
LOCATED ON UNIT NAMEPLATE
2 STAGE SCROLL
208-230/3/60 - 3 PHASE
LOCATED ON UNIT NAMEPLATE
15.49
EXPANSION VALVE
3.54
EXPANSION VALVE
4YCZ6048
*090[*115]
NO
5.3
R-410A
4YCZ6048
*096[120]
48000
1520
12 / 13.5 / 16
11.4/ 12.65 /15.1
71
72000 [90000]
80
30 / 60
[40 / 70]
3 / #37
[3 / #32]
SPINE FIN
2 / 24
23.57
3/8
PLATE FIN
4/15
5.0
3/8
4YCZ6060
*115
4YCZ6060
A3120C
57500
1950
73
90000
120000
80
30 / 60
3 / #32
23.57
18-EB28D1-12C-EN