T10000RT SERIES
POOL/SPA EQUIPMENT CONTROLS
CONTROL PANEL WITH TIME SWITCH FOR INDOOR/OUTDOOR USE
Suitable for Pool Equipment Control and for Direct Connection of Underwater
Lights
ELECTRICAL RATINGS: See inside Enclosure Door
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician.
...always disconnect electricity before servicing this control or the equipment connected to it.
Many of today's energy efficient pools and
spas utilize the advantages of a single electrical
panel, containing all the necessary controls
for the safe, efficient and automatic operation
of the pool/spa equipment. In addition, this
Panel can also be used to control any outdoor
equipment, sign or pump within its rated
capacity.
The Transformers supplied in these panels
are specifically designed to supply 12 volts
to underwater pool/spa lights. A grounded
shield between the primary and secondary
winding assures safe operation and the built-
in circuit protection will disconnect power to
the transformer in case of overload. These
transformers are suitable for direct connection
to underwater Pool and Spa lights.
The all-weather enclosure contains a heavy-
duty, industrial grade Time Switch. Also, it has
provisions to install switches inside as well as
a switch or GFCI receptacle on the outside.
The Time Switch can also accommodate an
optional heater control (fireman) switch.
The Control is designed to operate any pump,
within its rated capacity. However, if protection
to prevent dry start is required by the pump
manufacturer, it must be provided in addition
to this Control. Contact pump manufacturer
if not sure and/or for more details.
DANGER! TO AVOID RISK OF INJURY:
READ, FOLLOW AND SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
SERVICE MANUAL
Transformer
Input
60 Hz.
Rating
100W
120V. 1 Amp Max.
300W
120V. 3 Amp Max.
* Any combination of bulbs, any tap.
1
INSTALLATION
OPERATION &
Secondary Output
Lamp Watts*
Volts
100 Max.
12, 13 or 14
300 Max.
12, 13 or 14