What To Do If - IKEA SVAVANDE Manual

Island chimney hood
Hide thumbs Also See for SVAVANDE:
Table of Contents

Advertisement

ENGLISH

What to do if...

If there is a fault, first try to find a solution
yourself. If you are unable to resolve the
problem yourself, contact an authorised
service centre.
PROBLEM
Appliance not stable.
Appliance is not in horizontal
position.
Performance in terms of oil cap-
ture are not satisfying.
Appliance does not work.
The light does not work.
Noise of hood is higher than
customer expectation.
Button A light flashing once per
second.
Button A lights flashing twice
per second.
Before contacting the Authorised Service
Centre:
Turn the power back on to check whether the
problem has disappeared. If this is not the
case, turn it off and repeat the operation after
one hour. If the appliance still does not work
correctly after carrying out the checks listed
POSSIBLE CAUSE
The appliance is not correctly installed.
The appliance is not correctly installed.
Oil and grease on metal filters or
charcoal filters.
The appliance is not correctly connec-
ted.
The LED is broken.
Air outlet diameter in the wall is too
small, causing a pressure drop and an
increase in motor speed.
Product is installed in recirculation
mode.
More than one bend in the ventilation
duct.
Grease filter alarm.
Charcoal filter alarm.
In the event of improper use of the
appliance or installation carried out without
respecting the assembly instructions, it may
be necessary to pay for the visit of an
Authorised Service Centre technician, even
during the warranty period.
SOLUTION
Follow the Installation instruction enclosed to the appli-
ance.
Follow the Installation instruction enclosed to the appli-
ance.
Follow the cleaning frequency of filters as described in
the user manual.
Verify that the main cable is connected to the motor
group or the plug is connected to the socket.
For replacement, contact the Authorized Service Centre.
Follow the Installation instruction enclosed to the appli-
ance.
Product in recirculation mode(and using a charcoal filter)
will generate an higher noise than a product in extration
mode.
If the exhaust system in the building has multiple bend
in or a long distance, this can increase the noise of the
product.
Please clean grease filter and reset alarm. Refer to care
and cleaning guide for maintenance.
Press and hold the "C" button for approximately 2
seconds, with all the loads turned off (Motor+Lights), to
reset the grease filter saturation alarm. LED (A) flashes
three times to confirm.
Charcoal filter alarm. Please clean charcoal filter and reset
alarm. Refer to care and cleaning guide for maintenance.
Press and hold the "C" button for approximately 2
seconds, with all the loads turned off (Motor+Lights), to
reset the charcoal filter alarm. LED (A) flashes three times
to confirm.
in the troubleshooting guide and turning the
appliance back on, contact the Authorised
Service Centre clearly explaining the problem
and specifying:
• the type of fault;
• the model;
• the type and serial number of the appliance
(indicated on the data plate).
11

Advertisement

Table of Contents
loading

Table of Contents