Part Number:
This document describes how to install the IBM Ethernet Appliance J34S.
About This Guide .............................................................................................3
Step 1: Prepare the Site ...................................................................................5
Rack-Mounting Requirements ...................................................................5
Required Tools ..........................................................................................5
Step 2: Install the Mounting Hardware ............................................................6
Step 3: Install the Device .................................................................................7
Install the Device Using a Lift ....................................................................7
Install the Device Without a Mechanical Lift ...........................................10
Remove Components .......................................................................10
Lift the Chassis into the Rack ............................................................11
Reinstall Components ......................................................................12
Step 4: Connect the External Devices and IOC Cables ...................................13
Connect to a Network for Out-of-Band Management ...............................13
Connect a Management Console .............................................................13
Connect the IOC Cables ..........................................................................14
Step 5: Connect the Ground and Power Cables .............................................14
Connect the Grounding Cable .................................................................15
Connect Power to a DC-Powered Ethernet Appliance .............................17
Step 6: Perform the Initial Software Configuration ........................................19
Safety Warnings ............................................................................................24
Compliance Statements for EMC Requirements ............................................25
Canada ...................................................................................................25
European Union ......................................................................................25
J34S ........................................................................................................26
1

Advertisement

Table of Contents
loading

Summary of Contents for IBM Ethernet Appliance J34S

  • Page 1: Table Of Contents

    IBM Ethernet Appliance J34S Getting Started Guide April 2010 Part Number: This document describes how to install the IBM Ethernet Appliance J34S. Contents About This Guide .....................3 Step 1: Prepare the Site ...................5 Rack-Mounting Requirements ..............5 Required Tools ..................5 Step 2: Install the Mounting Hardware ............6 Step 3: Install the Device .................7...
  • Page 2 IBM Ethernet Appliance J34S Getting Started Guide Requesting Technical Support ...............27 Revision History ....................27...
  • Page 3: Contents About This Guide

    About This Guide About This Guide This guide contains information you need to install and configure the IBM Ethernet Appliance J34S quickly. For complete installation instructions, and instructions on installing additional modules such as cards and power supplies, see the IBM Ethernet Appliance J34S Hardware Guide at http://www.ibm.com/systems/support/networking...
  • Page 4 By installing different combinations of IOCs and SPCs, you can tailor both the number of network ports and the maximum security processing capacity to suit your network. Table 1 on page 4 describes the minimum system configuration for the IBM Ethernet Appliance J34S.
  • Page 5: Step 1: Prepare The Site

    CFMs to prevent damage to the device or power supplies. See the IBM Ethernet Appliance J34S Hardware Guide for information about supported configurations.
  • Page 6: Step 2: Install The Mounting Hardware

    IBM Ethernet Appliance J34S Getting Started Guide Phillips (+) screwdrivers, numbers 1 and 2 Electrostatic discharge (ESD) wrist strap (provided) Step 2: Install the Mounting Hardware The specific mounting hardware required depends on the type of rack being used. Use the appropriate procedure steps to install the mounting hardware for your situation.
  • Page 7: Step 3: Install The Device

    Ensure the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see the IBM Ethernet Appliance J34S Hardware Guide. Load the device onto the lift, making sure it rests securely on the lift platform (see Figure 6 on page 8).
  • Page 8 IBM Ethernet Appliance J34S Getting Started Guide Figure 6: Load the Device onto the Lift Using the lift, position the device in the rack: For two-post rack mounting, align the bottom hole in each mounting bracket with a hole in each rack rail.
  • Page 9 Step 3: Install the Device Figure 7: Installing the Device in a Two-Post Rack Figure 8: Installing the Device in a Four-Post Rack Install the remaining screws in each mounting bracket. Move the lift away from the rack. Visually inspect the alignment of the device. If the device is installed properly in the rack, all the mounting screws on one side of the rack should be aligned with the mounting screws on the opposite side, and the device should be level.
  • Page 10: Install The Device Without A Mechanical Lift

    IBM Ethernet Appliance J34S Getting Started Guide Install the Device Without a Mechanical Lift To install the device without a mechanical lift: Remove Components on page 10 Lift the Chassis into the Rack on page 11 Reinstall Components on page 12...
  • Page 11: Lift The Chassis Into The Rack

    Do not stack removed components. Lay each one on a flat surface. NOTE: For complete instructions on removing device components, see Installing the Ethernet Appliance Without a Mechanical Lift” in the IBM Ethernet Appliance J34S Hardware Guide. Lift the Chassis into the Rack Lifting the chassis and mounting it in a rack is a two person lift process.
  • Page 12: Reinstall Components

    Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the IBM Ethernet Appliance J34S Hardware Guide. Slide each component into the chassis evenly so that it does not become stuck or damaged.
  • Page 13: Step 4: Connect The External Devices And Ioc Cables

    Step 4: Connect the External Devices and IOC Cables NOTE: Make sure that all empty slots are covered with blank panels before operating the device. Step 4: Connect the External Devices and IOC Cables To connect external devices and IOC cables: Connect to a Network for Out-of-Band Management on page 13 Connect a Management Console on page 13 Connect the IOC Cables on page 14...
  • Page 14: Connect The Ioc Cables

    Connect the IOC Cables Have ready a length of the type of cable used by the IOC. For cable specifications, see the IBM Ethernet Appliance J34S Hardware Guide. If you are connecting a fiber IOC cable, the connector port may be covered by a rubber safety cap.
  • Page 15: Connect The Grounding Cable

    Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the IBM Ethernet Appliance J34S Hardware Guide. Place the grounding cable lug over the grounding point—a pair of M5 holes to the left of the power supply slots.
  • Page 16: Connect Power To An Ac-Powered Ethernet Appliance

    ESD points on the chassis. For more information about ESD, see the IBM Ethernet Appliance J34S Hardware Guide. Locate the power cord or cords you will use to connect the device to AC power.
  • Page 17: Connect Power To A Dc-Powered Ethernet Appliance

    Step 5: Connect the Ground and Power Cables Snap the wire bail over the power cord as shown in Figure 14 on page 17 to prevent the power cord from accidentally disengaging. Dress the power cord appropriately. Verify that the power cord does not block the air exhaust and access to device components or drape where people could trip on it.
  • Page 18 Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the IBM Ethernet Appliance J34S Hardware Guide. For each power supply: Remove the clear plastic cover protecting the terminal studs on the faceplate.
  • Page 19: Step 6: Perform The Initial Software Configuration

    Step 6: Perform the Initial Software Configuration Attach the negative (–) DC source power cable lug to the (input) terminal. Secure the cable lug to the terminal on the power supply, first with the square washer, then with the screw. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque.
  • Page 20 IBM Ethernet Appliance J34S Getting Started Guide [edit] root@# set system root-authentication plain-text-password New password: password Retype new password: password Configure an administrator account on the device. When prompted, enter the password for the administrator account. [edit] root@# set system login user admin class super-user authentication...
  • Page 21 Step 6: Perform the Initial Software Configuration Check the configuration for validity. [edit] admin@# commit check configuration check succeeds Commit the configuration to activate it on the device. [edit] admin@# commit commit complete Optionally, display the configuration to verify that it is correct. admin@# show ## Last changed: 2009-10-20 22:43:25 UTC version "9.6R2.11";...
  • Page 22 IBM Ethernet Appliance J34S Getting Started Guide interfaces { ge-0/0/0 { unit 0 { family inet { address 192.1.1.1/24; ge-0/0/1 { unit 0 { family inet { address 5.1.1.1/24; fxp0 { unit 0 { family inet { address 192.168.10.2/24; routing-options { static { route 0.0.0.0/0 next-hop 5.1.1.2;...
  • Page 23 Step 6: Perform the Initial Software Configuration admin@# commit Optionally, configure additional properties by adding the necessary configuration statements. Then commit the changes to activate them on the device. [edit] admin@# commit When you have finished configuring the device, exit configuration mode. [edit] admin@# exit admin@>...
  • Page 24: Safety Warnings

    Before installing the device, read the guidelines for site preparation in the IBM Ethernet Appliance J34S Hardware Guide to make sure that the site meets power, environmental, and clearance requirements for the Ethernet appliance. For the cooling system to function properly, the airflow around the chassis must be unrestricted.
  • Page 25: Compliance Statements For Emc Requirements

    When installing the device, do not use a ramp inclined more than 10 degrees. Manually installing the device is a two person lift process. Before lifting the chassis, remove components as described in the IBM Ethernet Appliance J34S Hardware Guide. To prevent injury, keep your back straight and lift with your legs, not your back.
  • Page 26: Hardware And Software Documentation For Ibm Ethernet Appliances J34S

    Table 3 on page 26 lists the hardware and software manuals and release notes for the IBM Ethernet Appliance J34S running JUNOS Software All documents are available at http://www.ibm.com/systems/support/networking/ Table 3: Hardware and Software Documentation for IBM Ethernet Appliance J34S Book Description Hardware...
  • Page 27 © Copyright International Business Machines Corporation 2008, 2009. All rights reserved. Printed in USA. US Government Users Restricted Rights—Use, duplication, or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both.