Advertisement

Quick Links

IBM Ethernet Appliance J56S
Getting Started Guide
April 2010
Part Number:
This document describes how to install the IBM Ethernet Appliance J56S.
About This Guide .............................................................................................3
Step 1: Prepare the Site ...................................................................................4
Rack-Mounting Requirements ...................................................................4
Required Tools ..........................................................................................5
Step 2: Install the Mounting Hardware ............................................................6
Open-Frame Rack ..............................................................................6
Step 3: Install the Device .................................................................................8
Install the Device Using a Lift ....................................................................8
Install the Device Without a Mechanical Lift ...........................................10
Remove Components .......................................................................11
Lift the Chassis into the Rack ............................................................11
Reinstall Components ......................................................................12
Step 4: Connect External Devices and IOC Cables .........................................13
Connect to a Network for Out-of-Band Management ...............................13
Connect a Management Console .............................................................13
Connect the IOC Cables ..........................................................................13
Step 5: Connect Ground and Power Cables ...................................................14
Connect the Grounding Cable .................................................................14
Connect Power to a DC-Powered Ethernet Appliance .............................16
Step 6: Perform Initial Software Configuration ..............................................18
Safety Warnings ............................................................................................23
Compliance Statements for NEBS ..................................................................25
1

Advertisement

Table of Contents
loading

Summary of Contents for IBM J56S

  • Page 1: Table Of Contents

    IBM Ethernet Appliance J56S Getting Started Guide April 2010 Part Number: This document describes how to install the IBM Ethernet Appliance J56S. Contents About This Guide .....................3 Step 1: Prepare the Site ...................4 Rack-Mounting Requirements ..............4 Required Tools ..................5 Step 2: Install the Mounting Hardware ............6 Install the Mounting Hardware in a Four-Post Rack or Cabinet or an Open-Frame Rack ................6...
  • Page 2 IBM Ethernet Appliance J56S Getting Started Guide Compliance Statements for EMC Requirements ..........25 Canada ....................25 European Union ..................25 Hardware and Software Documentation for IBM Ethernet Appliance J56S ......................26 Requesting Technical Support ...............27 Revision History ....................27...
  • Page 3: Contents About This Guide

    By installing different combinations of IOCs and SPCs, you can tailor both the number of gigabit ports and the maximum security processing capacity to suit your network. Table 1 on page 3 describes the minimum system configuration for the IBM Ethernet Appliance J56S.
  • Page 4: Step 1: Prepare The Site

    IBM Ethernet Appliance J56S Getting Started Guide Step 1: Prepare the Site Figure 1: Rack Clearance and Chassis Dimensions for the IBM Ethernet Appliance J56S Rack-Mounting Requirements You can install the device in a four-post rack or cabinet or an open-frame rack.
  • Page 5: Required Tools

    Step 1: Prepare the Site Ensure that the cabinet allows the chassis hot exhaust air to exit the cabinet without recirculating into the device. The device must be installed into a rack that is secured to the building structure. The device should be mounted at the bottom of the rack if it is the only unit in the rack.
  • Page 6: Step 2: Install The Mounting Hardware

    IBM Ethernet Appliance J56S Getting Started Guide Step 2: Install the Mounting Hardware To install the mounting hardware in a four-post rack or cabinet or an open-frame rack: Install the Mounting Hardware in a Four-Post Rack or Cabinet or an Open-Frame...
  • Page 7 Step 2: Install the Mounting Hardware Figure 2: Mounting Hardware for a Four-Post Rack or Cabinet Step 2: Install the Mounting Hardware...
  • Page 8: Step 3: Install The Device

    Ensure the rack is in its permanent location and is secured to the building. Ensure that the installation site allows adequate clearance for both airflow and maintenance. For details, see the IBM Ethernet Appliance J56S Hardware Guide. Load the device onto the lift, making sure it rests securely on the lift platform (see Figure 4 on page 9).
  • Page 9 Step 3: Install the Device Figure 4: Load the Device onto the Lift Using the lift, position the device in front of the rack or cabinet, centering it in front of the mounting shelf. Lift the chassis approximately 0.75 in. above the surface of the mounting shelf and position it as close as possible to the shelf.
  • Page 10: Install The Device Without A Mechanical Lift

    IBM Ethernet Appliance J56S Getting Started Guide Install the Device Without a Mechanical Lift To install the device without a mechanical lift: Remove Components on page 11 Lift the Chassis into the Rack on page 11 Reinstall Components on page 12...
  • Page 11: Remove Components

    Do not stack removed components. Lay each one on a flat surface. NOTE: For complete instructions on removing device components, see Install the Ethernet Appliance Without a Mechanical Lift” in the IBM Ethernet Appliance J56S Hardware Guide. Lift the Chassis into the Rack Lifting the chassis and mounting it in a rack is a three person lift process.
  • Page 12: Reinstall Components

    Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the IBM Ethernet Appliance J56S Hardware Guide. Slide each component into the chassis evenly so that it does not become stuck or damaged.
  • Page 13: Step 4: Connect External Devices And Ioc Cables

    Connect the IOC Cables Have ready a length of the type of cable used by the IOC. For cable specifications, see the IBM Ethernet Appliance J56S Hardware Guide. If the IOC cable connector port is covered by a rubber safety plug, remove the plug.
  • Page 14: Step 5: Connect Ground And Power Cables

    IBM Ethernet Appliance J56S Getting Started Guide WARNING: Do not look directly into a fiber-optic transceiver or into the ends of fiber-optic cables. Fiber-optic transceivers and fiber-optic cable connected to a transceiver emit laser light that can damage your eyes.
  • Page 15: Connect Power To An Ac-Powered Ethernet Appliance

    Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the IBM Ethernet Appliance J56S Hardware Guide. Place the grounding cable lug over the grounding point. The grounding point is sized for UNC 1/4-20 nuts.
  • Page 16: Connect Power To A Dc-Powered Ethernet Appliance

    IBM Ethernet Appliance J56S Getting Started Guide Figure 9: Connecting AC Power to the Ethernet Appliance Switch the AC switch on each power supply to the position ( ) and observe the status LEDs on each power supply faceplate. If an AC power supply is correctly...
  • Page 17 Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis. For more information about ESD, see the IBM Ethernet Appliance J56S Hardware Guide. For each power supply: Switch the circuit breaker on the power supply faceplate to the position.
  • Page 18: Step 6: Perform Initial Software Configuration

    IBM Ethernet Appliance J56S Getting Started Guide Secure the power cable lugs to the terminal studs on the power supply, first with the split washer, then with the nut. Apply between 23 lb-in. (2.6 Nm) and 25 lb-in. (2.8 Nm) of torque.
  • Page 19 Step 6: Perform Initial Software Configuration Configure an administrator account on the device. When prompted, enter the password for the administrator account. [edit] root@# set system login user admin class super-user authentication plain-text-password New password: password Retype new password: password Commit the configuration to activate it on the device.
  • Page 20 IBM Ethernet Appliance J56S Getting Started Guide configuration check succeeds Commit the configuration to activate it on the device. [edit] admin@# commit commit complete Optionally, display the configuration to verify that it is correct. admin@# show ## Last changed: 2009-10-20 22:43:25 UTC version "9.6R2.11";...
  • Page 21 Step 6: Perform Initial Software Configuration address 192.1.1.1/24; ge-0/0/1 { unit 0 { family inet { address 5.1.1.1/24; fxp0 { unit 0 { family inet { address 192.168.10.2/24; routing-options { static { route 0.0.0.0/0 next-hop 5.1.1.2; security { zones { security-zone trust { interfaces { ge-0/0/0.0;...
  • Page 22 IBM Ethernet Appliance J56S Getting Started Guide [edit] admin@# commit When you have finished configuring the device, exit configuration mode. [edit] admin@# exit admin@> Step 6: Perform Initial Software Configuration...
  • Page 23: Safety Warnings

    Before installing the device, read the guidelines for site preparation in the IBM Ethernet Appliance J56S Hardware Guide to make sure that the site meets power, environmental, and clearance requirements for the Ethernet appliance. For the cooling system to function properly, the airflow around the chassis must be unrestricted.
  • Page 24 When installing the device, do not use a ramp inclined more than 10 degrees. Manually installing the device is a three person lift process. Before lifting the chassis, remove components as described in the IBM Ethernet Appliance J56S Hardware Guide. To prevent injury, keep your back straight and lift with your legs, not your back.
  • Page 25: Compliance Statements For Nebs

    Compliance Statements for NEBS Compliance Statements for NEBS The equipment is suitable for installation as part of the Common Bonding Network (CBN). The equipment is suitable for installation in locations where the National Electrical Code (NEC) applies. The battery return connection is to be treated an isolated DC return (i.e. DC-I), as defined in GR-1089-CORE.
  • Page 26: Hardware And Software Documentation For Ibm Ethernet Appliance J56S

    Table 4 on page 26 lists the hardware and software manuals and release notes for IBM Ethernet appliance J56S running JUNOS Software. All documents are available at http://www.ibm.com/systems/support/networking/ Table 4: Hardware and Software Documentation for IBM Ethernet Appliance J56S Book Description Hardware...
  • Page 27: Requesting Technical Support

    © Copyright International Business Machines Corporation 2008, 2009. All rights reserved. Printed in USA. US Government Users Restricted Rights—Use, duplication, or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both.