Chamberlain SJ Owner's Manual page 7

Speed jackshaft operator
Table of Contents

Advertisement

Radio Controls
All radio controls must have dr y contact relay
outputs. Power for radio is to be supplied by an
outside source. Do not take power from the
components inside the electrical enclosure.
Additional Access Control Equipment
Locate any additional access control equipment as desired (but so that the door will be in clear sight of the person
operating the equipment), and connect to the terminal block in the electrical enclosure as shown on the FIELD
WIRING CONNECTIONS diagram. Any control with a normally (N.O.) isolated output contact may be connected
in parallel with the OPEN button. More than one device may be connected in this manner. Use 16 gauge wire or
larger for all controls. DO NOT USE THE CONTROL CIRCUIT TRANSFORMER (24VAC) IN THE OPERATOR
TO POWER ANY ACCESS CONTROL EQUIPMENT OTHER THAN A STANDARD RESIDENTIAL TYPE RADIO
RECEIVER.
Manual Release Brake
The operator is equipped with a internal interlock switch mounted to the brake assembly. When the brake is
manually dis-engaged the control circuit will be disabled, thereby preventing electrical operation of the door from
the control devices.
WARNING
IF CONTROL STATION CANNOT BE INSTALLED WHERE
DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN
THE CONTROL STATION IS USED TO ACTIVATE THE
DOOR, A REVERSING EDGE MUST BE INSTALLED ON
THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A
REVERSING EDGE UNDER THESE CIRCUMSTANCES
MAY RESULT IN SERIOUS PERSONAL INJURY OR
DEATH TO PERSONS TRAPPED BENEATH THE DOOR.
CAUTION
NOTICE:
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case the user will be required to correct
the interference at his own expense.
CONTROL WIRING (con't)
DO NOT USE RADIO CONTROLS WITH YOUR
OPERATOR UNLESS YOU HAVE INSTALLED
SOME TYPE OF ENTRAPMENT PROTECTION
DEVICE. THE USE OF RADIO CONTROLS
PRESENTS POTENTIAL HAZARDS DUE TO THE
USER'S ABILITY TO OPEN OR CLOSE THE
DOOR WHEN OUT OF SIGHT OF THE DOOR.
The operator has been pre-wired to accept
connection of a reversing edge device. Connect the
normally open contacts to terminals 5 and 6 located
on the LMPLC board. An auxiliary limit switch (yellow)
will deactivate the safety device during the last few
inches of the door's downward travel.