Lennox LM012CI-100V232-1X Service Manual page 55

Table of Contents

Advertisement

12. Remove magnet coil
Remove the screw fixing the magnet coil and then
remove the coil.
13. Remove valves and 4-way valve subassembly
Unsolder welding joint connecting the capillary,
the valve and the outlet pipe of condenser to
remove the capillary. Do not block the capillary
with welding slag during unsoldering.
Remove the 2 screws fixing the gas valve and
unsolder the welding point between the gas valve
and the air-return pipe to remove the gas valve.
(NOTE: Discharge the refrigerant completely
before unsoldering; when unsoldering, wrap the
gas valve with a wet cloth completely to avoid
damage to the valve caused by high temperature).
Remove the 2 screws fixing the liquid valve and
unsolder the welding joint connecting the liquid
valve to the Y-type pipe to remove the liquid valve.
Unsolder the welding joint connecting the 4-way
valve, the compressor and the condenser to
remove the 4-way valve.
14. Remove compressor
Remove the foot nuts on the compressor and then
remove the compressor.
52
magnet coil
4-way
valve
gas valve
foot nuts
Service Manual
liquid valve
compressor
Installation and Maintenance