  • Page 1 LENNOX LM036CI-100P432 LM036CO-100P432 LENNOX...
  • Page 3: Table Of Contents

    Content Operation Notices Precautions......................1 Parts Name......................6 Screen Operation Guide Buttons on remote controller .................7 Introduction for icons on display screen ..............7 Introduction for buttons on remote controller ............8 Function introduction for combination buttons.............11 Operation guide ....................12 Replacement of batteries in remote controller .............12 Emergency operation ..................13 Maintenance Clean and Maintenance..................13...
  • Page 4: Precautions

    Precautions WARNING Operation and Maintenance This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 5 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 6 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 7 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 8 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 9: Parts Name

    Parts name Indoor Unit air inlet panel horizontal louver air outlet cooling power receiver indicator indicator window display heating temp. drying indicator indicator indicator (Display content or position may be different from above remote control graphics, please refer to actual products) Outdoor Unit air inlet air outlet...
  • Page 10: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button MODE button SWING button button FAN button TIMER OFF button CLOCK button TIMER ON button SLEEP button TEMP button TURBO button X-FAN button I FEEL button button Introduction for icons on display screen Set fan speed I feel Send signal heating function...
  • Page 11: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: After putting through the power, the air conditioner will give out a sound. Operation indictor " " is ON (red indicator). After that, you can operate the air conditioner by using remote controller. Under on status, pressing the button on the remote controller, the signal icon "...
  • Page 12 Introduction for buttons on remote controller FAN button This button is used for setting Fan Speed in the sequence that goes from AUTO, , to , then back to Auto. Auto Low speed Medium speed High speed TIMER OFF button Press this button to initiate the auto-off timer.
  • Page 13 Introduction for buttons on remote controller unit displays set temperature; When selecting " " with remote controller, temperature indicator on indoor unit displays indoor ambient temperature; 3s later or within 3s it receives other remote controller signal that will return to display the setting temperature. Caution: This model hasn't outdoor ambient temperature display function.
  • Page 14: Function Introduction For Combination Buttons

    Function introduction for combination buttons Combination of " " and " " buttons: About lock controller is locked, is displayed. In this case, pressing any button, blinks three times. Combination of "MODE" and " " buttons: About switch between Fahrenheit and centigrade At unit OFF, press "MODE"...
  • Page 15: Operation Guide

    Operation guide After putting through the power, press "ON/OFF" button on remote controller to turn on the air conditioner. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. equired temperature. (Temperature can’t be adjusted under auto mode). Press "FAN"...
  • Page 16: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 17 Clean and maintenance Open panel Pull out the panel to a certain ) to clean panel cover tightl . WARNING...
  • Page 18 Clean and maintenance NOTICE: Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether circuit break, plug and socket are in good condition. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 19: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still Phenomenon Check items Solution (such as static electricity,stable the plug after about 3min, and voltage)? then turn on the unit again. within the signal receiving range? Indoor unit Select proper angle and point...
  • Page 20 Malfunction analysis Phenomenon Check items Solution fuse is burnt out? circuit break or fuse. Air condit- operate after stopping operation? on the unit again. for remote controller is correct? Mist is em- rapidly. After a while, indoor itted from temperature and humidity will idity is high? be decrease and mist will air outlet...
  • Page 21 Malfunction analysis Phenomenon Check items Solution Odours are such as furniture and cigarette, emitted etc. Air conditio- ner operates such as thunder, wireless power, and then turn on the abnormally devices, etc. unit again. Outdoor ating mode, it may generate unit has vapor, which is a normal vapor...
  • Page 22 Malfunction analysis Error Code When air conditioner status is abnormal, temperature indicator on indoor unit will ation of error code. Above indicator diagram is only Indoor for reference. Please refer to display actual product for the actual indicator and position. Error code Error code Troubleshooting...
  • Page 23: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 15cm At least 15cm Space to the wall Space to the obstruction Air inlet side 30cm Above Space to the wall 50cm Above Air outlet side Space to the wall Drainage pipe...
  • Page 24: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 13 Inner hexagon spanner 14 Measuring tape Note: Selection of installation location...
  • Page 25: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. circuit break. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 26: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3.
  • Page 27 Installation of indoor unit Indoor outdoor Note: opening the hole. The plastic expansion particles are 5-10 locally. Step four: outlet pipe 1. The pipe can be led out in the 2. When select leading out the pipe direction of right, rear right, left or from left or right, please cut off the rear left.
  • Page 28 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench 30~40 union nut pipe torque wrench indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape. insulating pipe Step six: install drain hose indoor unit.
  • Page 29 Installation of indoor unit 2. Make the power connection wire go cable-cross through the cable-cross hole at the back hole the front side. power connection wire with wire clip. N(1) yellow- blue black brown green Outdoor unit connection 4.Put wiring cover back and then tighten the screw. 5.Close the panel.
  • Page 30 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 31: Installation Of Outdoor Unit

    Installation of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. Note: installing the outdoor unit. Make sure the support can withstand at least four times of the unit weight.
  • Page 32 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw cap of valve and 3. Tighten the union nut with torque aim the pipe joint at the bellmouth of wrench by referring to the sheet pipe.
  • Page 33 Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: to prolong or shorten the distance. Step six: neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly.
  • Page 34: Vacuum Pumping

    Vacuum pumping Use vacuum pump 1. Remove the valve caps on the liquid valve and gas liquid valve piezometer valve and the nut of refri- gas valve gerant charging vent. refrigerant valve cap 2. Connect the charging hose charging vent nut of refrigerant gerant charging vent of gas charging vent...
  • Page 35: Check After Installation

    Check after installation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. It may cause condensation and water Is water drained well? dripping.
  • Page 36: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe fference. Max length Max length Cooling Max height Cooling Max height of connec- of connec- difference difference tion pipe tion pipe 4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe of connection pipe.
  • Page 37 Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m)
  • Page 38: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: E: Expand the port the distance of indoor unit and hard outdoor unit. mold expander pipe pipe pipe cutter Note: leaning...