Remote Commands - Mitsubishi Electric XD3200U Supplementary Manual

Controlling the projector using a personal computer
Hide thumbs Also See for XD3200U:
Table of Contents

Advertisement

ITEM
Projector status
Error status
The PC sends the command without attaching the data code to it. On the other hand, the projector attaches to
the received command its current operating status as the data code and send it back to the PC.
[Example]
When checking the currently selected input terminal (when the INPUT VIDEO is being selected).
(Values enclosed in quotation marks are ASCII codes.):
Command sent from the PC, etc.
'30' '30' '76' '49' '0D'
00vl

4.3 Remote commands

splash screen is being displayed, the splash screen is only canceled.)
The remote commands allow the computer to control the projector in the same way as by the remote control.
(Some operations cannot be controlled.) The remote commands have no data codes.
Button's name on remote
+/VOLUME
-/VOLUME
ZOOM/FOCUS
LENS SHIFT
KEYSTONE
MAGNIFY
PiP
AV MUTE
MENU
ENTER
AUTO POSITION
FREEZE
ASPECT
CE
Function
Character
ASCII
vST
76h 53h 54h
vER
76h 45h 52h
Status code returned
'30' '30' '76' '49' '76' '31' '0D'
00vlv1
(Not executable in stand-by mode. When the remote commands are sent while the
Function
Character
r06
72h 30h 36h
r07
72h 30h 37h
r0f
72h 30h 66h
r47
72h 34h 37h
r43
72h 34h 33h
r02
72h 30h 32h
r04
72h 30h 34h
ra6
72h 61h 36h
r53
72h 35h 33h
r2b
72h 32h 62h
r4f
72h 34h 66h
r59
72h 35h 39h
r54
72h 35h 34h
r10
72h 31h 30h
r09
72h 30h 39h
ra4
72h 61h 34h
re2
72h 65h 32h
re7
72h 65h 37h
0 (Stand-by mode),
1 (Within 1 minute after POWER-ON (warm-up mode)),
2 (POWER-ON mode (including state of warning)),
3 (Cooling mode),
4 (Abnormal state (including shutdown due to an error)),
5 (State of functioning (menu display, dialog display,
AV MUTE, PinP, MAGNIFY, FREEZE, etc.)),
6 (Awaiting password entry)
Reading out error data (3 digits, hexadecimal
numbers, total 9 bits)
(MSB) xb1, xb2... xb8, xb9, 0, 0, 0 (LSB)
xb1: Fan error
xb2: Lamp error (The lamp goes out or does not light.)
xb3: Lamp warning 1 (The lamp life has expired.)
xb4: Lamp warning 2 (The lamp life is expiring.)
xb5: Temperature error
xb6: The temperature warning is being indicated.
xb7: Fixed to 0.
xb8: Fixed to 0.
xb9: States of other component abnormality
from the projector
ASCII
6
Data (Receive)
Description
Command for checking the input
terminal
Check result (VIDEO)

Advertisement

Table of Contents
loading

Table of Contents