Remote Commands - Mitsubishi Electric WL6700LU Supplementary Manual

Controlling the projector using a personal computer
Hide thumbs Also See for WL6700LU:
Table of Contents

Advertisement

ITEM
Projector status
Error status
The PC sends the command without attaching the data code to it. On the other hand, the projector attaches to
the received command its current operating status as the data code and send it back to the PC.
[Example]
When checking the currently selected input terminal (when the INPUT VIDEO is being selected).
(Figures and symbols enclosed in quotation marks are ASCII codes.):
Sending commands
from the PC, etc.
'30' '30' '76' '49' '0D'
00vl

4.3 Remote commands

splash screen is being displayed, the splash screen is only canceled.)
Some remote control operations can be achieved by the remote command codes. The remote commands have
no data codes.
Button's name on remote
+/VOLUME
-/VOLUME
ZOOM/FOCUS
LENS SHIFT
KEYSTONE
MAGNIFY
SPLIT
AV MUTE
MENU
ENTER
AUTO POSITION
FREEZE
ASPECT
CE
Function
Character
ASCII
vST
76h 53h 54h
vER
76h 45h 52h
'30' '30' '76' '49' '76' '31' '0D'
00vlv1
(Not executable in stand-by mode. When the remote commands are sent while the
Function
Character
r06
72h 30h 36h
r07
72h 30h 37h
r0f
72h 30h 66h
r47
72h 34h 37h
r43
72h 34h 33h
r02
72h 30h 32h
r04
72h 30h 34h
ra6
72h 61h 36h
r53
72h 35h 33h
r2b
72h 32h 62h
r4f
72h 34h 66h
r59
72h 35h 39h
r54
72h 35h 34h
r10
72h 31h 30h
r09
72h 30h 39h
ra4
72h 61h 34h
re2
72h 65h 32h
re7
72h 65h 37h
0 (Stand-by mode),
1 (Within 1 minute after POWER-ON (warm-up mode)),
2 (POWER-ON mode (including state of warning)),
3 (Cooling mode),
4 (Abnormal state (including shutdown due to an error)),
5 (State of functioning (menu display, dialog display,
MUTE, SPLIT, FREEZE)),
6 (Awaiting password entry)
Reading out error data (3 digits, hexadecimal
numbers, total 9 bits)
(MSB) xb1, xb2... xb8, xb9, 0, 0, 0 (LSB)
xb1: Fan error
xb2: Lamp error (The lamp goes out or does not light.)
xb3: Lamp warning 1 (The lamp life has expired.)
xb4: Lamp warning 2 (The lamp life is expiring.)
xb5: Temperature error
xb6: The temperature warning is being indicated.
xb7: Lamp cover open error
xb8: Filter cover open error
xb9: States of other component abnormality
Status code
from the projector
ASCII
5
Data (Receive)
Description
Command for checking the input
terminal
Check result (VIDEO)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wl6700uWl6700u

Table of Contents