Technical data

Safety
Safety class according to EN 50178
Degree of protection according to EN
60529
Approvals
Flame resistance
UL identifier
Electrical data
Overvoltage category
Power supply
Power consumption, max., at 28.8 V
Current consumption, max., at 20.4 V
Mechanical data
Dimensions W x H x D (mm)
Weight (kg)
Perm. vertical mounting positions
Tightening torques, max.
Mechan. stability
Climatic environmental conditions
Classification of the climatic environment
Heat dissipation
Condensation and ice formation
Supply air
Max. installation altitude
Temperature limit values (storage)
Temperature limit values (operation)
Temperature change
ONE MCP Part 2: MCP 2400.9c
Equipment Manual, 09/2022, A5E52294261B AA
1)
5)
MCP 2400.9c
Front: IP54
CE / EAC / UL
UL 94 V-1
MCPS2105-585210B-0492151AA0
Secondary circuit supplied from primary circuits up to Cat. III
(OVC III), 300 V AC
24 V DC (20.4 V ... 28.8 V)
+ 10 USB ports
+ 2 handwheels
+24 V load on X515/X516
Total
585 x 210 x 75
M3: 0.5 Nm standard
M4: 1 Nm
M5: 1.5 Nm standard
Grounding: 3 Nm, hold bottom nut in place
According to UL 61010
3K3 according to EN 60721‑3-3
By natural convection
Not permitted
Without corrosive gases, dusts and oils
Use and operation
Up to 1000 m without derating
From 1000 m to 4000 m with linear ambient temperature
derating, -0.5 K per 100 m
-40 ... 70 °C (cyclic)
0 ... 45 °C (front)
0 ... 55 °C (rear)
Max. 30 K/h
III; PELV
Rear: IP00
2)
3)
4)
10x 2.6 W
2x 1 W
16x 0.15 A
115 W
4.7 A
3.1
0° - 90°
3)
5
21