Mounting

Note
• To ensure the most ideal location, test the SITRANS AS100 by clamping the Sensor to the
application, and running a trial period to determine the system's performance. The
acoustic emission level can be monitored by a voltmeter across the analog output. Refer
to Interconnection (Page 11).
• Coating the contact surfaces with grease enhances the propagation of acoustic emissions
to the Sensor.
Direct Mounting
Clearance Hole
Insert mounting post
through hole in device be-
ing monitored and fasten
with customer supplied
washers and nut.
Note
To ensure proper coupling, the face of the Sensor nut must be tight to the application
surface.
7
Mounting Method
Clearance hole
Drill and Tap
Mounting Disc
Extension Tab
Drill and Tap
Screw mounting post into
threaded hole in device
being monitored.
Acoustic Coupling and Sensitivity
Good
Good
Good
Fair
Contact
Weld or bond mounting
post to device being moni-
tored. When welding, first
remove the acoustic sensor
from the housing.
Operating Instructions, 04/2021, A5E31952194-AC
3
SITRANS AS100