Mounting
Accessory Mounting
Extension Tab
Screw Sensor into threaded hole of tab, and
fasten onto device being monitored.
Note
• If welding, weld must be a continuous bead. Tacking does not provide sufficient acoustical
coupling.
• Do not arc weld on equipment connected to a SITRANS AS100. Remove the SITRANS
AS100 or disconnect electrically to avoid current flowing through the sensor.
• If gluing, use Loctite 326 adhesive, or equivalent. Follow manufacturer's instructions to
ensure proper adhesion.
8
Mounting Disc
Screw Sensor into disc, after welding or
bonding disc onto device being monitored.
Operating Instructions, 04/2021, A5E31952194-AC
SITRANS AS100