11. Product Specifications; 11.1 En 14624:2020 Test Results - Bosch IR LD 1.0 Operator's Manual

Co2 leak detector
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 21

11. Product specifications

Property
Sensor life
Power Supply
Battery
Operating Time (full charge)
Battery Charge Time
Battery Charging Temperature 0°C to 45°C
Warm up time
Operating Environment
Storage Environment
LCD
Warranty
IP Rating
Altitude
Pollution Degree
Dimensions (excluding probe) 216 x 83 x 51 mm
Overall probe length
Weight

11.1 EN 14624:2020 Test Results

The IR LD 1.0 must be checked for compliance with minimum perfor-
mance standards as per EN 14624:2020 on a calibrated leak standard at
least on an annual basis. More frequent checks may be required based on
application and region; check with your local authority to ensure compli-
ance with all local regulations.
EN 14624:2020 Test Results
Static lower detection limit
Dynamic lower detection limit
Dynamic lower detection limit in a
contaminated environment
Response time
2
Zeroing time
2
Recovery time
2
g/a - gram/annum,
S - Second
1
2
Bosch Automotive Service Solutions GmbH
Product specifications | IR LD 1.0 | 37 | en
IR LD 1.0
> 5 years
5V DC 1.0 A charger
Lithium-ion 3350 mAh Battery
Approximately 8 hours continuous
Approximately 3 hours
Normally 50–60 seconds; 90 seconds Max.
Indoor/Outdoor Use
-20°C to 50°C and 0 to 95% RH, non-condensing
Note: Use in temperatures below 0°C should be
limited. Extended warm-up time is recommended
before use in low temperature environments.
-20°C to 65°C and 0 to 95% RH, non-condensing
61 mm; 240 x 320 Pixels full color display
2 years (includes battery and sensor)
IP51
<3000 m
4
413 mm
412 g
Units
g/a
1
g/a
1
g/a
1
S
S
S
R744 (CO2)
4
5
10
<1
35
SP01502142 | 14.03.2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

R744

Table of Contents