PRODUCT IDENTIFICATION
This section will identify the models covered and the changes per each model group from one release to the next.
Model # Manufacturing #
P1211203F - P1211205F
GCIS***CX**
GCIS***CX**
P1230603F - P1230605F
GCIS***CX**
P1230703F - P1230705F
GUIV***DX**
P1227403F - P1227408F
GUIV***CX**
P1230203F - P1230208F
GUIV***CX**
P1230303F - P1230308F
Gas Furnace Counterflow/Horizontal Induced Draft S 2-Stage, Air Command 80
SSE II Furnace "C" Third Design Series "X" NOx Certified.
40" 80% two-stage furnace featuring integrated electronic ignition control, silicon
carbide ignitor, two-stage gas valve, two-speed induced draft blower,
electrodepositioned textured steel cabinet and 409 stainless steel tubular
heat exchanger.
Gas Furnace Counterflow/Horizontal Induced Draft S 2-Stage, Air Command 80
SSE II Furnace "C" Third Design Series "X" NOx Certified.
40" 80% two-stage furnace featuring integrated electronic ignition control, silicon
carbide ignitor, two-stage gas valve, two-speed induced draft blower, prepainted
textured steel cabinet and 409 stainless steel tubular heat exchanger.
G as Furnace C ounterflow/Horizontal I nduced Draft S 2-Stage, Air Command 80
SSE II Furnace "C" Third Design Series "X" NOx Certified.
40" 80% two-stage furnace featuring integrated electronic ignition control, silicon
carbide ignitor, two-stage gas valve, two-speed induced draft blower,
electrodepositioned textured steel cabinet and 409 stainless steel tubular heat
exchanger. Change from embossed bottom knock-out to perforated bottom knock-
out and addition of internal side filter retention.
Gas Furnace Upflow/Horizontal Induced Draft Variable Speed, 2-Stage, Air
Command 80 SSE II Q Furnace "D" Fourth Design Series "X" NOx Certified.
40" 80% two-stage variable speed furnace featuring integrated electronic ignition
control, silicon carbide ignitor, two-stage gas valve, two-speed induced draft blower,
variable speed circualtor blower, electrodepositioned textured steel cabinet and 409
stainless steel tubular heat exchanger.
Gas Furnace Upflow/Horizontal Induced Draft Variable Speed, 2-Stage, Air
Command 80 SSE II Q Furnace "C" Third Design Series "X" NOx Certified.
40" 80% two-stage variable speed furnace featuring integrated electronic ignition
control, silicon carbide ignitor, two-stage gas valve, two-speed induced draft blower,
prepainted textured steel cabinet and 409 stainless steel tubular heat exchanger.
G as Furnace U pflow/Horizontal I nduced Draft V ariable Speed, 2-Stage, Air
Command 80 SSE II Q Furnace "C" Third Design Series "X" NOx Certified.
40" 80% two-stage variable speed furnace featuring integrated electronic ignition
control, silicon carbide ignitor, two-stage gas valve, two-speed induced draft blower,
electrodepositioned textured steel cabinet and 409 stainless steel tubular heat
exchanger. Change from embossed bottom knock-out to perforated bottom knock-
out and addition of internal side filter retention.
Description
9