2. Install the 90º O-ring fittings and position the fittings at
10 o'clock.
3. Using a wrench, secure the fitting nut.
STEP 5
Installing Inflation Valves
Appropriate procedures must be employed for
effective assembly of the air inflation valve located on
each air bottle cylinder. Installation torque and
cleanliness should be addressed when installing.
1. Using a hex key wrench, remove shipping plugs from
both air bottle cylinders.
EXCESS PACKING OIL MAY RELEASE FROM THE
AIR BOTTLE CYLINDER. AVOID CONTACT WITH
HYDRAULIC FLUIDS. USE PERSONAL PROTECTIVE
EQUIPMENT. IF HYDRAULIC FLUID COMES IN
CONTACT WITH EYES, GETS INTO THE
BLOODSTREAM OR IS SWALLOWED, PLEASE
CONSULT A DOCTOR IMMEDIATELY.
2. Wrap the threads on the two air inflation valves with
Teflon™ tape. When applying tape, wrap it three times in
direction shown below.
3. Carefully thread each air inflation valve into each air
bottle cylinder as shown. NOTE: It is strongly
recommended that valve cores be started by hand to
minimize cross-threading.
4. Gently tighten each inflation valve.