About This User Guide Pls read all the content of the user guide carefully to use the products safely and effectively. You are advised of keeping it properly for your using reference. Disclaimer Please do not dismantle the product or tear up the seal on it, otherwise we won’t provide warranty or replacement service.
Page 3
V0.1.0 Output all product information by setting the code 2016.01.27 V0.1.1 1D added to identify both bar codes at the same time 2016.03.25 1. Communication mode added to support AUTO UK V0.1.2 and AUTO UV V 2016.05.06 2. DM add the multi-code reading mode V0.1.3 Add 2D code packet format description 2016.05.25...
Page 5
2.2.1 Reset to default configuration ....................8 2.2.2 Communication mode setting ....................8 2.2.3 Decode scanning time setting ....................9 2.2.4 trigger mode setting ........................ 9 2.2.5 scan time interval setting of the same barcode (continuous scanning mode) ....10 2.2.6 scan time interval setting of the same barcode (Auto mode) ..........10 2.2.7 Data uploading format ......................10 2.2.8 Turn on/Turn off configuration code ..................11 2.2.9 Enable\Disable sending setting code ..................11...
Page 7
2.4.21 Enable/Disable QR ......................20 2.4.22 Enable/Disable single/double QR ..................20 2.4.23 Enable/Disable MicroQRCode ....................21 2.4.24 Enable/Disable Data Matrix(DM) ..................21 2.4.25 Enable/Disable Maxi Code ....................21 2.4.26 Enable/Disable Aztec Code ....................21 2.4.27 Enable/Disable Chinese code .....................21 2.5 serial port communication setting ....................22 2.5.1 Baud rate setting ........................22 2.5.2 check bit setting ........................22 2.5.3 stop bit setting ........................23 2.5.4 The retard of characters ......................23...
Page 8
3、Serial port instructions ..........................27 3.1 Basic Configuration ..........................27 3.2 Volume and light setting ........................28 3.3 Enable\Disable decode function ......................30 3.4 serial port communication setting ....................32 3.5 Prefix and suffix setting ........................33 3.6 Mark barcode transfer type setting ....................33 appendix .................................35 Appendix 1 Number setting code ......................35 Appendix 2 set prefix and suffix by serial port instructions ..............37 Appendix 3 : barcode sample ........................41...
1、Product Introduction This user guide applies to E3000(H)(E3100(H)), which identify 1D&2D barcodes by 2D image scanning pattern. The scanners above are of strong identification capability, and support automatic continuous scanning mode with fast and flexible scanning speed. In this chapter, we will introduce the instruction of scanner with pictures, please compare to the scanner you bought when reading this user guide, which is good for your understanding.
1.3 Product display 1.3.1 External view 1.3.2 Size(mm) 1.4 Interface description Product standard interfaces are: RS232 (DB9 orifice), TTL, USB Keyboard(USD HID), Keyboard and Wiegand. Standard interface of different products are not the same, please confirm before purchase, other interfaces can be customized according to customer needs.
1.5 Communication port Interface NO. Name Type Description Empty Spare DC power supply DC3.3V Digital ground Input Serial input port TTL level output Serial input port TTL level USB_D- Input / output USB_D- signal USB_D+ Input / output USB_D+ signal Empty Spare output...
Page 13
1.6.3 LED 1.7 Communication port The scanner must be connected to a host to operate. Host can be a PC, POS machine, intelligent terminal with USB or RS-232 interface. USB interface on host RS-232 RS-232 interface on host...
Page 14
1.8 Supported code system Support code system as follows, you can open the relevant code through the menu or serial command Default minimum bar code type bar code ID open length √ CODE 39 √ CODE 128 √ UPC/EAN CODEBAR CODE 93 CODE 11 INTERLEAVED 2 OF 5...
1.10 Maintenance * The window must be kept clean, the supplier do not bear the guarantee responsibility due to the improper maintenance. * Avoid the window being wear and tear or scratched by hard object * Use the hairbrush to remove the stain on the window * Clean the window with a soft cloth, such as lens cleaning cloth * Spraying liquid onto the window is prohibited.
Reset to default configuration 2、barcode setting Option and function setting mainly through reading a series of special barcodes. In this chapter, we will provide you a detailed introduction of the options and functions available for user setting, and the corresponding setup code. This method of setting the scanning is direct, easy to understand and user friendly.
Page 17
Reset to default configuration 2.2.3 Decode scanning time setting This barcode is used to set the most longest decoding time in the range of 0.50 to 25.5 second when scanner reading barcode. First scan below barcode enter setting mode, then scan three numbers from the appendix.
Page 18
Reset to default configuration Host trigger mode setting step: 1、wake up operation: Send 0x00 first, then send effective instruction after 50ms, (factory default is power saving mode ) 2、start scan:04 E4 04 00 FF 14 3、end scan:04 E5 04 00 FF 13 4、after end scan, scanner module time-out in 800ms without working remark:...
Page 19
Reset to default configuration Enter 2.2.8 Turn on/Turn off configuration code Enable Configuration Code Disable Configuration Code 2.2.9 Enable\Disable sending setting code Enable sending setting code Disable sending setting code 2.2.10 Power mode In power saving mode scanner module time-out after a period of time without working. In continuous power mode scanner module keep awake.
Page 20
Reset to default configuration high level:1, middle level:8, low level:15. Default: high level. Special sensitivity High sensitivity Middle sensitivity Low sensitivity 2.2.12 Invoice automatic identification and output (only for China) close(default) open 2.2.13 Invoice character type (only for China) English character--default UTF8 character...
Page 21
Reset to default configuration 2.2.14 Invoice type (only for China) special invoice(default) Plain invoice 2.3 Volume and light setting 2.3.1 indicator light setting To set the meaning of the indicator light. Represent decode Represent power 2.3.2 Successful decode indicate setting If decode successfully the indicator light on for a while, on condition that the indicator light has been set to represent decode.
Page 22
Reset to default configuration Volume-Middle Volume-High 2.3.4 Mute setting Turn on or off all volume 2.3.5 Starting up sound setting 2.3.6 setting code volume 2.3.7 LED setting...
Page 23
Reset to default configuration LED on when reading Always on Always off 2.3.8 positioning lamp setting Always on when reading Always on Always off 2.4 Enable\Disable decode function 2.4.1 code system character output 2.4.2 Enable/Disable UPC-A Enable...
Page 28
Reset to default configuration Disable GS1 DataBar(RSS) 2.4.20 Enable/Disable PDF417 Enable PDF417 Disable PDF417 2.4.21 Enable/Disable QR Enable QR Disable QR 2.4.22 Enable/Disable single/double QR Enable single QR(default) Enable double QR Enable single and double QR code...
Page 29
Reset to default configuration 2.4.23 Enable/Disable MicroQRCode Enable MicroQRCode Disable MicroQRCode 2.4.24 Enable/Disable Data Matrix(DM) Enable Data Matrix(DM) Disable Data Matrix(DM) 2.4.25 Enable/Disable Maxi Code Enable Maxi Code Disable Maxi Code 2.4.26 Enable/Disable Aztec Code Enable Aztec Code Disable Aztec Code 2.4.27 Enable/Disable Chinese code Enable Chinese code...
Reset to default configuration Disable Chinese code 2.5 serial port communication setting 2.5.1 Baud rate setting Baud rate means the bit number transfer in each second. The baud rate of the scanner module must match with the receive-data host. If the baud rate doesn’t match the host, then the data might be wrong or can’t remote host.
Page 31
Reset to default configuration Even digital Choose MARK as Odd-even check bit and Odd-even check digital always is “1”. Mark Choose SPACE as Odd-even check bit and Odd-even check digital always is “0”. SPACE If you don’t need Odd-even check bit, choose null. Null odd-even check bit 2.5.3 stop bit setting Every character has a stop bit in the end during the data transmission which means the end of...
Page 32
Reset to default configuration retard of characters(default 0ms) 2.6 Prefix and suffix setting 2.6.1 Prefix and suffix setting You can set at most one prefix and two suffix attach to the scan data. To set this prefix and suffix, you need to scan four number (means four barcode in Appendix II and II) based on ASCII.
Page 33
Reset to default configuration Barcode + suffix 2 Barcode + suffix 1 + suffix 2 Prefix + barcode Prefix + barcode+ suffix 1 Prefix + barcode+ suffix 2 Prefix + barcode+ suffix 1 + suffix 2 2.7 Mark barcode transfer type setting 2.7.1 Disable mark barcode transfer type Disable mark barcode transfer type 2.7.2 Enable mark barcode transfer type...
Page 34
Reset to default configuration 2.8 Chinese character encode 2.8.1 Disable Chinese character encode Disable Chinese character encode 2.8.2 GBK(GB2312) Be suited to TXT、Excel type software display. Default setting. GBK(GB2312) 2.8.3 UNICODE Be suited to QQ、WORD type software display. UNICODE...
Reset to default configuration 3、Serial port instructions The serial port version of these products can set all basic setting 、 light and volume、 decode function、 communication mode 、prefix and suffix and so on by serial port instructions. Serial port instructions format: command + check bit Remark 1: Check bit is the last two bits at the back of the instructions, computation rule: sum all byte, then perform NOT(negation) and plus “1”...
Page 36
Reset to default configuration (continuous scanning 0.5s: 07 C6 04 08 00 89 05 FE 99 mode) 3s:07 C6 04 08 00 89 1E FE 80 Null :08 C6 04 08 00 F2 05 00 FE 2F CRLF:08 C6 04 08 00 F2 05 01 FE 2E End mark Enter:08 C6 04 08 00 F2 05 02 FE 2D TAB: 08 C6 04 08 00 F2 05 03 FE 2C...
Page 37
Reset to default configuration Off: 08 C6 04 08 00 F2 0B 00 FE 29 Decode indicator light On: 08 C6 04 08 00 F2 0B 01 FE 28 Volume-Low:07 C6 04 08 00 8C 02 FE 99 Volume setting Volume-Middle: 07 C6 04 08 00 8C 01 FE 9A Volume-High: 07 C6 04 08 00 8C 00 FE 9B On: 08 C6 04 08 00 F2 0C 01 FE 27...
Page 38
Reset to default configuration 3.3 Enable\Disable decode function Instructions(HEX ) Function off:07 C6 04 08 00 2D 00 FE FA on:07 C6 04 08 00 2D 02 FE F9 code system character output For example:C ode 93 read 012345678905 and come out result with G012345678905 G means Code93 off:07 C6 04 08 00 01 00 FF 26...
Page 40
Reset to default configuration off:08 C6 04 08 00 F1 3D 01 FD F7 MicroQRCode on:08 C6 04 08 00 F1 3D 00 FD F8 off:08 C6 04 08 00 F0 24 01 FE 11 DataMatrix on:08 C6 04 08 00 F0 24 00 FE 12 off:08 C6 04 08 00 F0 26 00 FE 10 MaxiCode on:08 C6 04 08 00 F0 26 01 FE 0F...
Page 41
Reset to default configuration 1ms: 07 C6 04 08 00 6E 01 FE B8 The retard of characters 99ms: 07 C6 04 08 00 6E 63 FE B8 3.5 Prefix and suffix setting Instructions(HEX ) Function 0B C6 04 08 00 69 (Prefix)68(suffix 1)6A(suffix 2)check bit For example:set prefix as 31,suffix 1 as 32 Prefix and suffix setting suffix 2 as 33...
Page 42
Reset to default configuration Code 128, ISBT 128, GS1-128 UPC/EAN, Coupon (UPC portion) Codabar Code 93 Code 11 Interleaved 2 of 5 Discrete 2 of 5, IATA 2 of 5 Code 39 Trioptic, Bookland EAN, Han Xin GS1 D ataBar PDF417 Data Matrix(DM) Aztec Code...
Page 43
Reset to default configuration appendix Appendix 1 Number setting code When setting needs exact number, scan the barcode below to set numbers. Number Barcode...
Page 44
Reset to default configuration Cancel Change setting or cancel one wrong barcode by scan this barcode.
Reset to default configuration Appendix 2 set prefix and suffix by serial port instructions Add prefix and suffix to the barcode: 1. set scanning data transport format (parameter 0Xe2) to what you need. 2. You need to change the ASCII code into hex system so that you can import these codes you want to set in the prefix 1(0x69), suffix 1(0x68) or suffix 2(0x6A).