  • Page 1 NADAMOO User Guide This User Guide Applies to E3000 (H) (E3100 (H) ) 第 1 页 共 50 页 V1.1.1...
  • Page 2: Version Record

    About This User Guide Pls read all the content of the user guide carefully to use the products safely and effectively. You are advised of keeping it properly for your using reference. Disclaimer Please do not dismantle the product or tear up the seal on it, otherwise we won’t provide warranty or replacement service.
  • Page 3 V0.1.0 Output all product information by setting the code 2016.01.27 V0.1.1 1D added to identify both bar codes at the same time 2016.03.25 1. Communication mode added to support AUTO UK V0.1.2 and AUTO UV V 2016.05.06 2. DM add the multi-code reading mode V0.1.3 Add 2D code packet format description 2016.05.25...
  • Page 4 Catalog 1、Product Introduction ..........................1 1.1 Main feature ............................1 1.2 Unpack your device ........................... 1 1.3Product display ........................... 2 1.3.1 External view ........................... 2 1.3.2 Size(mm) ..........................2 1.4 Interface description .......................... 2 1.5 Communication port .......................... 3 1.6 Peripheral circuit diagram ......................... 4 1.6.1 buzzer .............................
  • Page 5 2.2.1 Reset to default configuration ....................8 2.2.2 Communication mode setting ....................8 2.2.3 Decode scanning time setting ....................9 2.2.4 trigger mode setting ........................ 9 2.2.5 scan time interval setting of the same barcode (continuous scanning mode) ....10 2.2.6 scan time interval setting of the same barcode (Auto mode) ..........10 2.2.7 Data uploading format ......................10 2.2.8 Turn on/Turn off configuration code ..................11 2.2.9 Enable\Disable sending setting code ..................11...
  • Page 6 2.3.8 positioning lamp setting ......................15 2.4 Enable\Disable decode function ......................15 2.4.1 code system character output ....................15 2.4.2 Enable/Disable UPC-A ......................15 2.4.3 Enable/Disable UPC-E ......................16 2.4.4 Enable/Disable EAN-8 ......................16 2.4.5 Enable/Disable EAN-13 ......................16 2.4.6 Enable/Disable Bookland EAN(ISBN) ..................16 2.4.7 Bookland EAN(ISBN) ......................17 2.4.8 UPC/EAN Addendum Code ....................17 2.4.9 Convert UPC-E TO UPC-A ....................17 2.4.10 Enable/Disable Code 128 ....................17...
  • Page 7 2.4.21 Enable/Disable QR ......................20 2.4.22 Enable/Disable single/double QR ..................20 2.4.23 Enable/Disable MicroQRCode ....................21 2.4.24 Enable/Disable Data Matrix(DM) ..................21 2.4.25 Enable/Disable Maxi Code ....................21 2.4.26 Enable/Disable Aztec Code ....................21 2.4.27 Enable/Disable Chinese code .....................21 2.5 serial port communication setting ....................22 2.5.1 Baud rate setting ........................22 2.5.2 check bit setting ........................22 2.5.3 stop bit setting ........................23 2.5.4 The retard of characters ......................23...
  • Page 8 3、Serial port instructions ..........................27 3.1 Basic Configuration ..........................27 3.2 Volume and light setting ........................28 3.3 Enable\Disable decode function ......................30 3.4 serial port communication setting ....................32 3.5 Prefix and suffix setting ........................33 3.6 Mark barcode transfer type setting ....................33 appendix .................................35 Appendix 1 Number setting code ......................35 Appendix 2 set prefix and suffix by serial port instructions ..............37 Appendix 3 : barcode sample ........................41...
  • Page 9: Product Introduction

    1、Product Introduction This user guide applies to E3000(H)(E3100(H)), which identify 1D&2D barcodes by 2D image scanning pattern. The scanners above are of strong identification capability, and support automatic continuous scanning mode with fast and flexible scanning speed. In this chapter, we will introduce the instruction of scanner with pictures, please compare to the scanner you bought when reading this user guide, which is good for your understanding.
  • Page 10: Product Display

    1.3 Product display 1.3.1 External view 1.3.2 Size(mm) 1.4 Interface description Product standard interfaces are: RS232 (DB9 orifice), TTL, USB Keyboard(USD HID), Keyboard and Wiegand. Standard interface of different products are not the same, please confirm before purchase, other interfaces can be customized according to customer needs.
  • Page 11: Communication Port

    1.5 Communication port Interface NO. Name Type Description Empty Spare DC power supply DC3.3V Digital ground Input Serial input port TTL level output Serial input port TTL level USB_D- Input / output USB_D- signal USB_D+ Input / output USB_D+ signal Empty Spare output...
  • Page 12 1.6 Peripheral circuit diagram 1.6.1 buzzer 1.6.2 button...
  • Page 13 1.6.3 LED 1.7 Communication port The scanner must be connected to a host to operate. Host can be a PC, POS machine, intelligent terminal with USB or RS-232 interface. USB interface on host RS-232 RS-232 interface on host...
  • Page 14 1.8 Supported code system Support code system as follows, you can open the relevant code through the menu or serial command Default minimum bar code type bar code ID open length √ CODE 39 √ CODE 128 √ UPC/EAN CODEBAR CODE 93 CODE 11 INTERLEAVED 2 OF 5...
  • Page 15: Maintenance

    1.10 Maintenance * The window must be kept clean, the supplier do not bear the guarantee responsibility due to the improper maintenance. * Avoid the window being wear and tear or scratched by hard object * Use the hairbrush to remove the stain on the window * Clean the window with a soft cloth, such as lens cleaning cloth * Spraying liquid onto the window is prohibited.
  • Page 16: Barcode Setting

    Reset to default configuration 2、barcode setting Option and function setting mainly through reading a series of special barcodes. In this chapter, we will provide you a detailed introduction of the options and functions available for user setting, and the corresponding setup code. This method of setting the scanning is direct, easy to understand and user friendly.
  • Page 17 Reset to default configuration 2.2.3 Decode scanning time setting This barcode is used to set the most longest decoding time in the range of 0.50 to 25.5 second when scanner reading barcode. First scan below barcode enter setting mode, then scan three numbers from the appendix.
  • Page 18 Reset to default configuration Host trigger mode setting step: 1、wake up operation: Send 0x00 first, then send effective instruction after 50ms, (factory default is power saving mode ) 2、start scan:04 E4 04 00 FF 14 3、end scan:04 E5 04 00 FF 13 4、after end scan, scanner module time-out in 800ms without working remark:...
  • Page 19 Reset to default configuration Enter 2.2.8 Turn on/Turn off configuration code Enable Configuration Code Disable Configuration Code 2.2.9 Enable\Disable sending setting code Enable sending setting code Disable sending setting code 2.2.10 Power mode In power saving mode scanner module time-out after a period of time without working. In continuous power mode scanner module keep awake.
  • Page 20 Reset to default configuration high level:1, middle level:8, low level:15. Default: high level. Special sensitivity High sensitivity Middle sensitivity Low sensitivity 2.2.12 Invoice automatic identification and output (only for China) close(default) open 2.2.13 Invoice character type (only for China) English character--default UTF8 character...
  • Page 21 Reset to default configuration 2.2.14 Invoice type (only for China) special invoice(default) Plain invoice 2.3 Volume and light setting 2.3.1 indicator light setting To set the meaning of the indicator light. Represent decode Represent power 2.3.2 Successful decode indicate setting If decode successfully the indicator light on for a while, on condition that the indicator light has been set to represent decode.
  • Page 22 Reset to default configuration Volume-Middle Volume-High 2.3.4 Mute setting Turn on or off all volume 2.3.5 Starting up sound setting 2.3.6 setting code volume 2.3.7 LED setting...
  • Page 23 Reset to default configuration LED on when reading Always on Always off 2.3.8 positioning lamp setting Always on when reading Always on Always off 2.4 Enable\Disable decode function 2.4.1 code system character output 2.4.2 Enable/Disable UPC-A Enable...
  • Page 24 Reset to default configuration Disable 2.4.3 Enable/Disable UPC-E Enable Disable 2.4.4 Enable/Disable EAN-8 Enable Disable 2.4.5 Enable/Disable EAN-13 Enable Disable 2.4.6 Enable/Disable Bookland EAN(ISBN) Enable Disable...
  • Page 25 Reset to default configuration 2.4.7 Bookland EAN(ISBN) Bookland ISBN-10 Bookland ISBN-13 2.4.8 UPC/EAN Addendum Code Disable UPC/EAN Addendum Code Only identify UPC/EAN with addendum code Auto identify UPC/EAN Addendum code 2.4.9 Convert UPC-E TO UPC-A Enable Convert UPC-E to UPC-A Disable Convert UPC-E to UPC-A 2.4.10 Enable/Disable Code 128 Enable...
  • Page 26 Reset to default configuration Disable 2.4.11 Enable/Disable GS1-128 Enable GS1-128 Disable GS1-128 2.4.12 Enable/Disable Code 39 Enable Code 39 Disable Code 39 2.4.13 Enable/Disable Code 93 Enable Code 93 Disable Code 93 2.4.14 Enable/Disable Code 11 Enable Code 11 Disable Code 11...
  • Page 27 Reset to default configuration 2.4.15 Enable/Disable ITF25 Enable ITF25 Disable ITF25 2.4.16 Enable/Disable industrial ITF25 Enable industrial ITF25 Disable industrial ITF25 2.4.17 Enable/Disable Codabar Enable Codabar Disable Codabar 2.4.18 Enable/Disable MSI Enable MSI Disable MSI 2.4.19 Enable/Disable GS1 DataBar(RSS) 14 Enable GS1 DataBar(RSS) 14...
  • Page 28 Reset to default configuration Disable GS1 DataBar(RSS) 2.4.20 Enable/Disable PDF417 Enable PDF417 Disable PDF417 2.4.21 Enable/Disable QR Enable QR Disable QR 2.4.22 Enable/Disable single/double QR Enable single QR(default) Enable double QR Enable single and double QR code...
  • Page 29 Reset to default configuration 2.4.23 Enable/Disable MicroQRCode Enable MicroQRCode Disable MicroQRCode 2.4.24 Enable/Disable Data Matrix(DM) Enable Data Matrix(DM) Disable Data Matrix(DM) 2.4.25 Enable/Disable Maxi Code Enable Maxi Code Disable Maxi Code 2.4.26 Enable/Disable Aztec Code Enable Aztec Code Disable Aztec Code 2.4.27 Enable/Disable Chinese code Enable Chinese code...
  • Page 30: Serial Port Communication Setting

    Reset to default configuration Disable Chinese code 2.5 serial port communication setting 2.5.1 Baud rate setting Baud rate means the bit number transfer in each second. The baud rate of the scanner module must match with the receive-data host. If the baud rate doesn’t match the host, then the data might be wrong or can’t remote host.
  • Page 31 Reset to default configuration Even digital Choose MARK as Odd-even check bit and Odd-even check digital always is “1”. Mark Choose SPACE as Odd-even check bit and Odd-even check digital always is “0”. SPACE If you don’t need Odd-even check bit, choose null. Null odd-even check bit 2.5.3 stop bit setting Every character has a stop bit in the end during the data transmission which means the end of...
  • Page 32 Reset to default configuration retard of characters(default 0ms) 2.6 Prefix and suffix setting 2.6.1 Prefix and suffix setting You can set at most one prefix and two suffix attach to the scan data. To set this prefix and suffix, you need to scan four number (means four barcode in Appendix II and II) based on ASCII.
  • Page 33 Reset to default configuration Barcode + suffix 2 Barcode + suffix 1 + suffix 2 Prefix + barcode Prefix + barcode+ suffix 1 Prefix + barcode+ suffix 2 Prefix + barcode+ suffix 1 + suffix 2 2.7 Mark barcode transfer type setting 2.7.1 Disable mark barcode transfer type Disable mark barcode transfer type 2.7.2 Enable mark barcode transfer type...
  • Page 34 Reset to default configuration 2.8 Chinese character encode 2.8.1 Disable Chinese character encode Disable Chinese character encode 2.8.2 GBK(GB2312) Be suited to TXT、Excel type software display. Default setting. GBK(GB2312) 2.8.3 UNICODE Be suited to QQ、WORD type software display. UNICODE...
  • Page 35: Basic Configuration

    Reset to default configuration 3、Serial port instructions The serial port version of these products can set all basic setting 、 light and volume、 decode function、 communication mode 、prefix and suffix and so on by serial port instructions. Serial port instructions format: command + check bit Remark 1: Check bit is the last two bits at the back of the instructions, computation rule: sum all byte, then perform NOT(negation) and plus “1”...
  • Page 36 Reset to default configuration (continuous scanning 0.5s: 07 C6 04 08 00 89 05 FE 99 mode) 3s:07 C6 04 08 00 89 1E FE 80 Null :08 C6 04 08 00 F2 05 00 FE 2F CRLF:08 C6 04 08 00 F2 05 01 FE 2E End mark Enter:08 C6 04 08 00 F2 05 02 FE 2D TAB: 08 C6 04 08 00 F2 05 03 FE 2C...
  • Page 37 Reset to default configuration Off: 08 C6 04 08 00 F2 0B 00 FE 29 Decode indicator light On: 08 C6 04 08 00 F2 0B 01 FE 28 Volume-Low:07 C6 04 08 00 8C 02 FE 99 Volume setting Volume-Middle: 07 C6 04 08 00 8C 01 FE 9A Volume-High: 07 C6 04 08 00 8C 00 FE 9B On: 08 C6 04 08 00 F2 0C 01 FE 27...
  • Page 38 Reset to default configuration 3.3 Enable\Disable decode function Instructions(HEX ) Function off:07 C6 04 08 00 2D 00 FE FA on:07 C6 04 08 00 2D 02 FE F9 code system character output For example:C ode 93 read 012345678905 and come out result with G012345678905 G means Code93 off:07 C6 04 08 00 01 00 FF 26...
  • Page 39 Reset to default configuration off:07 C6 04 08 00 0E 00 FF 19 GS1-128 on:07 C6 04 08 00 0E 01 FF 18 off:07 C6 04 08 00 54 00 FE D3 ISBT 128 on:07 C6 04 08 00 54 01 FE D2 off:07 C6 04 08 00 00 00 FF 27 Code 39 on:07 C6 04 08 00 00 01 FF 26...
  • Page 40 Reset to default configuration off:08 C6 04 08 00 F1 3D 01 FD F7 MicroQRCode on:08 C6 04 08 00 F1 3D 00 FD F8 off:08 C6 04 08 00 F0 24 01 FE 11 DataMatrix on:08 C6 04 08 00 F0 24 00 FE 12 off:08 C6 04 08 00 F0 26 00 FE 10 MaxiCode on:08 C6 04 08 00 F0 26 01 FE 0F...
  • Page 41 Reset to default configuration 1ms: 07 C6 04 08 00 6E 01 FE B8 The retard of characters 99ms: 07 C6 04 08 00 6E 63 FE B8 3.5 Prefix and suffix setting Instructions(HEX ) Function 0B C6 04 08 00 69 (Prefix)68(suffix 1)6A(suffix 2)check bit For example:set prefix as 31,suffix 1 as 32 Prefix and suffix setting suffix 2 as 33...
  • Page 42 Reset to default configuration Code 128, ISBT 128, GS1-128 UPC/EAN, Coupon (UPC portion) Codabar Code 93 Code 11 Interleaved 2 of 5 Discrete 2 of 5, IATA 2 of 5 Code 39 Trioptic, Bookland EAN, Han Xin GS1 D ataBar PDF417 Data Matrix(DM) Aztec Code...
  • Page 43 Reset to default configuration appendix Appendix 1 Number setting code When setting needs exact number, scan the barcode below to set numbers. Number Barcode...
  • Page 44 Reset to default configuration Cancel Change setting or cancel one wrong barcode by scan this barcode.
  • Page 45: Ascii Code

    Reset to default configuration Appendix 2 set prefix and suffix by serial port instructions Add prefix and suffix to the barcode: 1. set scanning data transport format (parameter 0Xe2) to what you need. 2. You need to change the ASCII code into hex system so that you can import these codes you want to set in the prefix 1(0x69), suffix 1(0x68) or suffix 2(0x6A).
  • Page 46 Reset to default configuration 1033 ‘ 1034 1035 1036 1037 1038 & ‘ 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 1050 1051 1052 1053 1054 1055 1056 1057 1058 1059 1060 < 1061 1062 > 1063 1064 1065 1066...
  • Page 47 Reset to default configuration 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 1087 1088 1089 1090 1091 1092 1093 1094 1095 ‘ 1096 1097 1098 1099 1100 1101 1102 1103 1104 1105 1106 1107 1108 1109 1110 1111 1112 1113...
  • Page 48 Reset to default configuration 1119 1120 1121 1122 1123 1124 1125 1126 1127...
  • Page 49 Reset to default configuration Appendix 3 : barcode sample Name Barcode sample Remark EAN13 UPC-A EAN8 Default data: 1234565 UPC-E Encoded data: c01235d Codabar Code93 Code39(Regular) Encoded data: *Code 39 Code 39(FullASCII)