3.9
8. Step: Downloading the hardware configuration to the target
hardware
Procedure
Step
Activity
1
Switch back to HW Config
Download the hardware configuration to the CPU by calling the PLC > Download ... command.
2
Also close the HW Config by calling the Station > Exit command.
3.10
9. Step: Configuration of the SINAMICS drive with S7T Config
Procedure
Step
Activity
1
In SIMATIC Manager, double-click "Technological Objects" to open S7T Config.
Result: "Technology Objects Management" opens. The system automatically runs S7T Config if you have
not configured any technological objects yet, as in this example.
You may also run S7T Config without using "Technology Objects Management". Select the "Technological
Objects" object and then select the Options > Configure the technology command.
2
Save the current project data by selecting the Project > Save and recompile all command.
3
Change to the online mode by selecting the Project > Connect to target system command.
CPU 317T-2 DP: Controlling a SINAMICS S120
Getting Started, 03/2008, A5E00480391-03
3.9 8. Step: Downloading the hardware configuration to the target hardware
Result
Result
Learning units
25