Travis Industries GS2/MV Manual

Basic wall mount remote installation with ac adapter

Advertisement

Quick Links

GS2/MV Basic Wall Mount Remote Installation

Compatibility

Radiant Large GSB2 & MV
Radiant Medium GSB2 & MV
Radiant Small GSB2 & MV

Packing List

Remote Transmitter
Remote Receiver/Battery Box
(4) AA batteries & (3) AAA batteries
(1) AC Adapter
(1) Power Harness Adapter (with additional
Molex connector plug)
(1) Power Cord
(1) Receiver Adapter Harness (comes attached
to receiver)
(1) Strain Relief
(2) Strain Relief Brackets (Insert and Stove)
(1) 8-32 nut
(1) ¼" drive screw
(2) zip-ties
(1) Switch Blank
Page 1 of 18
with AC Adapter
SKU# 99300696
42 PB Linear GSB2 & MV
54 PB Linear GSB2 & MV
72 PB Linear GSB2 & MV
17602250 - 10/7/22
Northfield MV
Berkshire MV
Greenfield MV
36 PB CF GSB2 & MV
42 PB CF GSB2 & MV
Travis Industries, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Travis Industries GS2/MV

  • Page 1: Compatibility

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Compatibility     Radiant Large GSB2 & MV 42 PB Linear GSB2 & MV Northfield MV 36 PB CF GSB2 & MV     Radiant Medium GSB2 & MV 54 PB Linear GSB2 &...
  • Page 2: Table Of Contents

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Warnings The transmitter and receiver are radio frequency devices. Placing the transmitter in or near metal may severely reduce the signal range. Turn off power to the heater during installation or maintenance (unplug or turn off at the breaker).
  • Page 3: Overview

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Overview This kit supplies a basic wall-mount remote kit with an AC adapter to power the remote receiver. The basic installation is the same for MV and GSB stoves and inserts. This kit can also be used with MV and GSB fireplaces however, the way the kit connects to AC power is slightly different than with the inserts and stoves (see fireplace installation section for details).
  • Page 4 GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 RADIANT STOVE NOTE: If a blower is being uesd, install the blower kit first and discard the power cord and strain relief bracket from this kit. With the blower kit installed follow the steps below to electricly ground the accessories to the appliance belly pan.
  • Page 5 GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 2. Install the power cord with a strain relief clamp into the bracket. Feed the Molex end of the power cord through the hole in the bracket. Close to the end of the wire insulation place the strain relief on the wire with the sloped end facing the plug end of the cord.
  • Page 6 GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 4. Connect the green and white wires to the corresponding On/Off switch wires. 5. Connect the blue and white wires from the back of the receiver to the AC adapter. The insulation that covers the quick connects on the AC adapter are different colors.
  • Page 7: Steps Specific To Mv Fireplace And Insert Installation

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Steps Specific to MV Fireplace and Insert Installation This set of installation instructions shows a summary of the remote installation. For detailed instructions on the placement of the receiver and other details, refer to the installation manual included with your appliance.
  • Page 8: Steps Specific To Mv Stove Installation

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Steps Specific to MV Stove Installation This set of installation instructions shows a summary of the remote installation. For detailed instructions on the placement of the receiver and other details, refer to the installation manual included with your appliance.
  • Page 9: Steps Specific To Gsb2 Installation

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Steps Specific to GSB2 Installation This set of installation instructions shows a summary of the remote installation. For detailed instructions on the placement of the receiver and other details, refer to the installation manual included with your appliance.
  • Page 10: Wiring Diagram Mv

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Wiring Diagram MV Page 10 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 11: Wiring Diagram Gsb2

    GS2/MV Basic Wall Mount Remote Installation with AC Adapter SKU# 99300696 Wiring Diagram GSB2 Page 11 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 12: Operating Instructions

    See the installation instructions for details. These batteries power the receiver. The batteries also act as a power backup in case the household (AC) current goes out (GSB2 units only). Page 12 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 13: Direct Fireplace Operation

    REMOTE – Fireplace is controlled by the transmitter. Figure 4 NOTE: When the receiver switch is turned to ON or OFF, the thermostat and burner on/off operating functions will not work on the transmitter. Page 13 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 14: Remote Operation

    NOTE: When the batteries start to get low, the IFC will beep intermittently. When the batteries are nearly depleted, the IFC will no longer beep. See “Receiver Batteries” on page 16). Page 14 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 15 Use the up or appear here. down buttons to adjust the target temperature. NOTE: If the transmitter batteries go dead while in thermostat setting, the appliance will shut off after approximately 24 hours. Page 15 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 16: Low Battery Indicator

    Display Fahrenheit or Celsius  With the system in the “OFF” position, press both the MODE and THERMOSTAT buttons simultaneously to toggle between Fahrenheit (F) and Celsius (C). Page 16 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 17: Power Outages

    Repeat this process to toggle the thermostat function to the desired setting. When "SET" appears, the thermostat function is enabled. When "CLR" appears, the thermostat function is disabled. Page 17 of 18 17602250 - 10/7/22 Travis Industries, Inc.
  • Page 18: Disabling Modes From The Remote

    Press the "up" button to activate ("SET") the mode selected. Press the "down" button to clear ("CLR") the mode selected. Release the on/off button to complete programming. Page 18 of 18 17602250 - 10/7/22 Travis Industries, Inc.