11. Safety devices
Type of protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Thermal protection
protection
Terminal protection program
(Discharge temp.)
Compressor
protection
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Type of protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Thermal protection program
protection
Thermal protection program
(Discharge temp.)
Compressor
protection
Thermal protection program
(Outdoor temp.)
(Only in COOL or DRY mode)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
- 79 -
Model
AOUH09LPAS1
250 V, 15 A
250 V, 5 A
217±32 °F (103±18 °C)
Fan motor stop
203±32 °F (95±18 °C)
Fan motor restart
230 °F (110 °C)
Compressor stop
After 7 minutes
Compressor restart
5 °F (-15°C)
Compressor stop
14 °F (-10°C)
Compressor restart
Model
AOUH12LPAS1
250 V, 15 A
250 V, 5 A
217±32 °F (103±18°C)
Fan motor stop
203±32 °F (95±18°C)
Fan motor restart
230 °F (110 °C)
Compressor stop
After 7 minutes
Compressor restart
5 °F (-15°C)
Compressor stop
14 °F (-10°C)
Compressor restart
11. Safety devices