10. Electrical characteristics

Model name
Voltage
Power supply
Frequency
MCA *1
Starting current
MAX. CKT. BKR *3
Power cable
Wiring spec.
*2
Connection
cable *4
*1: Minimum Circuit Ampacity (Calculation based on UL60335-2-40)
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Maximum Circuit Breaker
*4: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
V
Hz
A
A
A
AWG
Size
AWG
Limited wiring
ft (m)
length
- 78 -
AOUH09LPAS1
208/230~
60
9.7
3.7
15
14
14
69 (21)
AOUH12LPAS1
4.9
10. Electrical characteristics