Description; Unpacking; Supplied Accessories - Panasonic FV-10VEC2R Installation And Operating Instructions Manual

Energy recovery ventilator
Hide thumbs Also See for FV-10VEC2R:
Table of Contents

Advertisement

DESCRIPTION

The Panasonic Energy Recovery Ventilator (ERV) uses 2 blower fans driven by 2 DC motors.
The motor is designed to have an extended service life with reduced energy consumption.
It also incorporates a thermal-cutoff for safety.
The exhaust air (EA) duct includes an electric damper to prevent backdrafting. The outside
air (OA) duct includes an electric damper to prevent backdrafting.
Energy Recovery Introduction: Compared to an HRV (Heat Recovery Ventilator), the ERV can
also transfer humidity and recover energy from that humidity. The ERV can exchange energy
between the stale EA and the "fresh" OA, transferring heat and moisture into the incoming
cold air in a heating climate and pre-cooling and reducing the humidity of the incoming hot
air in a cooling climate. This tempering and treatment of the required ventilation air helps
maintain a fresh environment even when the heating or cooling system is not operating.
Indoor
Stale air
Heat&
Moisture
Fresh air
<Heating Climate>

UNPACKING

Unpack and remove unit carefully from carton.
Refer to the supplied accessories list to verify that all parts are presented.

SUPPLIED ACCESSORIES

Part name
Hanger
Hanger
Wall bracket
L plate
Screw
(M4X8)
Long screw
(ST4.2X20)
Plug cover
Installation and
operating instructions
Limited warranty
4
Outdoor
Exhaust air
(EA)
Outside air
(OA)
Appearance
Indoor
Stale air
Fresh air
<Cooling Climate>
Outdoor
Heat&
Exhaust air
Moisture
(EA)
Outside air
(OA)
Quantity
1
4
1
4
12
12
4
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents